 Inspect spark plug for damage, and clean with a wire
brush before reinstalling. If insulator is cracked or
chipped, spark plug should be replaced. For replacement
spark plug, see Product Specifications earlier in this
manual or the accompanying engine manual, if applicable.
 Measure plug gap. The correct gap is 0.028−0.031 in.
(0.7-0.8 mm). To widen gap, if necessary, carefully bend
the ground (top) electrode. To lessen gap, gently tap
ground electrode on a hard surface.
 Seat spark plug in position; thread in by hand to prevent
cross-threading.
 Tighten with wrench to compress washer. If spark plug
is new, use 1/2 turn to compress washer appropriate
amount. If reusing old spark plug, use 1/8 to 1/4 turn for
proper washer compression.
NOTE: An improperly tightened spark plug will become
very hot and could damage the engine.
CLEANING THE EXHAUST PORT AND
MUFFLER
Depending on the type and amount of lubricant used and/
or your operating conditions, the exhaust port and muffler
may become blocked with carbon deposits. If you notice
a power loss, you may need to remove these deposits to
restore performance. We highly recommend that only quali-
fied service technicians perform this service.
SPARK ARRESTOR
See Figure 26.
NOTICE:
This product is equipped with a spark arrestor that has
been evaluated by the USDA Forest Service; however,
product users must comply with Federal, State, and local
fire prevention regulations. Check with appropriate au-
thorities. Contact customer service or a qualified service
center to purchase a replacement spark arrestor.
 Inspect the spark arrestor screen for breaks or holes.
Replace if necessary.
 Use a brush (not provided) to remove carbon deposits
from the spark arrestor screen as needed.
MAINTENANCE
TRANSPORTING
 Turn the engine switch OFF ( O ).
 Allow 30 minutes of "cool down" time before transporting
the machine. Make sure engine and exhaust of unit are
cool.
 Do not drop or strike unit or place under heavy objects.
 If transporting in a vehicle, securely restrain the generator.
 Provide a plastic sheet or absorbent pad below the gen-
erator to catch any drips of lubricant.
BATTERY REMOVAL AND PREPARATION
FOR RECYCLING
Consult your local waste authority for information regarding
available recycling and/or disposal options.
WARNING:
Upon removal, cover the battery's terminals with
heavy-duty adhesive tape. Do not attempt to destroy or
disassemble battery or remove any of its components.
Lead acid batteries must be recycled or disposed of
properly. Also, never touch both terminals with metal
objects and/or body parts as short circuit may result.
Keep away from children. Failure to comply with these
warnings could result in fire and/or serious injury.
Page 20 — English
To preserve natural resources, please recycle
or dispose of batteries properly.
This product uses lead acid batteries. Local,
state or federal laws may prohibit disposal of
batteries in ordinary trash.

Publicité