Noise Data - Ammann APH 6530 ACEforce Traduction Du Mode D'emploi Original

Masquer les pouces Voir aussi pour APH 6530 ACEforce:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Drive
Control (forward/reverse)
4. Operating speed
5. Vibration
Centrifugal power
Vibration frequency
6. Superficial power
Base unit
w. mount. brackets 75 mm
w. mount. brackets 150 mm
7. Noise and vibration data
The following noise and vibration data according to EC Machinery Directive in the version (2006/42/EC), was determined, taking into account the
following standards and directives. In operational use, values can deviate depending on the prevailing conditions.
1)

7.1 Noise data

The noise data specified in Appendix 1, sub-clause 1.7.4.u of the EC Machinery Directive is for:
Sound pressure level at the workplace L
Measured sound power level L
WA,m
Guaranteed sound power level L
The noise values were determined, taking into account the following directives and standards:
Directive 2000/14/EC / EN ISO 3744 / EN 500-4
7.2 Vibration data
Hand/arm vibration values according to Appendix 1, sub-clause 3.6.3.1 of the EC Machinery Directive:
Total vibration value of the acceleration a
Uncertainty K
The acceleration value was determined, taking into account the following directives and standards:
EN 500-4 / DIN EN ISO 5349
1)
As the permissible rating sound level of 85 dB (A) can be exceeded by this machine, operators must wear hearing protectors.
APH 6530 ACEforce
PA
WA,g
hv
hydraulic
hydraulic
0 - 37 m/min
65 kN
55 Hz
up to 1056 m²/h
up to 1344 m²/h
up to 1632 m²/h
95,0 dB
107 dB
109 dB
2
6.4 m/s
1.0 m/s
32
2. Technical data
APH 100-20 ACEforce
0 - 28 m/min
80 kN
40 Hz
up to 1090 m²/h
up to 1350 m²/h
up to 1600 m²/h
93,3 dB
2
8.4 m/s
2