Code
Description
Transducers Failures
Pr-01
Circuit A Discharge Transducer Failure
Pr-02
Circuit B Discharge Transducer Failure
Pr-03
Circuit C Discharge Transducer Failure
Pr-04
Circuit A Suction Transducer Failure
Pr-05
Circuit B Suction Transducer Failure
Pr-06
Circuit C Suction Transducer Failure
Pr-07
Circuit A Reclaim Pumpdown Pressure Transducer
Pr-08
Circuit B Reclaim Pumpdown Pressure Transducer
Pr-10
Circuit A Oil Pressure Transducer
Pr-11
Circuit B Oil Pressure Transducer
Pr-12
Circuit C Oil Pressure Transducer
Pr-13
Circuit A Economizer Pressure Transducer
Pr-14
Circuit B Economizer Pressure Transducer
Pr-15
Circuit C Economizer Pressure Transducer
Pr-16
Circuit A Free Cooling Pump Inlet Pressure Transducer
Pr-17
Circuit A Free Cooling Pump Outlet Pressure Transducer
Pr-18
Circuit B Free Cooling Pump Inlet Pressure Transducer
Pr-19
Circuit B Free Cooling Pump Outlet Pressure Transducer
Pr-20
Circuit C Free Cooling Pump Inlet Pressure Transducer
Pr-21
Circuit C Free Cooling Pump Outlet Pressure Transducer
Pr-22
Circuit A Heatpump Approach Pressure Transducer
Pr-23
Circuit B Heatpump Approach Pressure Transducer
Pr-24
Water Pressure 1 transducer failure
Water Heat Exchanger Leaving Fluid Transducer
Pr-25
Water Pressure 2 transducer failure
Pr-26
Water Pressure 3 transducer failure
Pr-27
Water Pressure 4 transducer failure
Pr-28
Water Pressure too high
Pr-29
Water Pressure too low - pump cavitaion risks
Pr-30
Water filter dirty
Pr-201
Supply Air Pressure Transducer Failure
Pr-202
Pressure Drop accros Supply Fan Transducer Failure
Pr-203
Pressure Drop accros Extract Fan Transducer Failure
Pr-204
Pressure Drop accros Heat Exchanger Transducer Failure
Sr-nn
Service maintenance alert Number # nn
Other Sensors Failures
se-201
Room Pollution Sensor Failure
se-202
Adiabatic Cooler Sensor Failure
se-1
Setpoint Offset Potentiometer Failure
Thermistors Failures
th-01
Water Heat Exchanger Entering Fluid Thermistor
th-02
Water Heat Exchanger Leaving Fluid Thermistor
th-03
Circuit A Defrost Thermistor Failure
th-04
Circuit B Defrost Thermistor Failure
th-06
Condenser Entering Fluid Thermistor Failure
th-07
Condenser Leaving Fluid Thermistor Failure
th-08
Reclaim Condenser Entering Thermistor Failure
th-09
Reclaim Condenser Leaving Thermistor Failure
th-10
OAT Thermistor Failure
th-11
MASTER/Slave Common Fluid Thermistor Failure
th-12
Circuit A Suction Gas Thermistor Failure
th-13
Circuit B Suction Gas Thermistor Failure
th-14
Circuit C Suction Gas Thermistor Failure
th-15
Circuit A Discharge Gas Thermistor Failure
th-16
Circuit B Discharge Gas Thermistor Failure
th-17
Circuit C Discharge Gas Thermistor Failure
th-18
Circuit A Condenser Subcooling Liquid Thermistor Failure
th-19
Circuit B CondenserSubcooling Liquid Thermistor Failure
th-21
Space Temperature Thermistor Failure
th-23
Cooler heater feedback thermistor Failure
th-24
Circuit A Economizer Gas Thermistor Failure
th-25
Circuit B Economizer Gas Thermistor Failure
th-26
Circuit C Economizer Gas Thermistor Failure
th-30
Circuit A Free Cooling Liquid Thermistor Failure
th-31
Circuit B Free Cooling Liquid Thermistor Failure
th-32
Master/Slave Common Heat Fluid Thermistor Failure
82
Formule de calcul appliqué
Le code des alarmes Pr-nn est calculé de la façon sui-
vante:
Code= 12000 + nn
Exemple pour une alarme Pr-202: nn= 202
Code Alarme NSM correspondant à Pr-202= 12202
Le code des alarmes Sr-nn est calculé de la façon sui-
vante:
Code= 13000 + nn
Exemple pour une alarme Sr-201: nn= 201
Code Alarme NSM correspondant à Sr-201= 13201
Le code des alarmes se-nn est calculé de la façon sui-
vante:
Code= 14000 + nn
Exemple pour une alarme Sr-201: nn= 1
Code Alarme NSM correspondant à se-1= 14001
Le code des alarmes th-nn est calculé de la façon suivante:
Code= 15000 + nn
Exemple pour une alarme th-34: nn= 34
Code Alarme NSM correspondant à th-34= 15034