Settings Menu - Relay Output; Settings Menu - Statistics - aqua HC 997 Serie Manuel De Programmation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

HC997-999 – MOD. A
Digital multifunction solenoid metering pump
Settings menu – Relay output
4.6.7
Settings menu – Statistics
4.6.8
ADSP9000026
This menu allows to set the functioning of the relay output (OUT RELAY) that can be
normally open or normally closed.
Press the
Press the
key to go at the previous menu.
18/09/2015 Rev.1.5
keys to choose between Open or Close.
This menu allows to read the statistics: total (Tot) and partial
(Par).
N. Strokes Tot
Indicates the total strokes performing by the pump.
Equ. Days Tot
Indicates the total working days of the pump.
Alim Day Tot
Indicates the total days that the pump has been powered.
Dose l Tot
Indicates the total mL dosed by the pump.
Strokes Par
Indicates the number of strokes performed by the pump since
the last reset.
Equ. Days Par
Indicates the working days of the pump since the last reset.
Alim Day Par
Indicates the days that the pump has been powered since the
last reset.
Dose l Par
Indicates the mL dosed by the pump since the last reset.
The reset erase only the partial statistics.
Press the
key to go back at the previous entry or menu.
SETTINGS AND CALIBRATION
37/100
ENGLISH

Publicité

Table des Matières
loading

Table des Matières