HC997-999 – MOD. A
Digital multifunction solenoid metering pump
Settings menu – Date and clock
4.6.2
Settings menu – Calibration
4.6.3
Settings menu – Units of measurement
4.6.4
ADSP9000026
This menu allow to set the date and clock..
Press the
Press the
key to move the cursor on the next field, the value to modify is blinking.
Press the
key to go back at the previous menu or move the cursor at the
previous field.
This menu allows to set the flow rate in mL of the pump in
100 strokes.
To perform the calibration following this procedure:
2. Priming the pump, the chemical has to go out from the
delivery.
3. Positioning a graduate container (at least 250 mL) on
the suction of the pump.
4. Save the quantity of the chemical inside the container
(L1).
5. Enter in the calibration menu and activate the pump.
6. A countdown will start.
7. When the pump stops, save the remaining quantity of
chemical inside the container (L2).
8. Press the
is the difference between L1- L2 and then press the
key to confirm.
18/09/2015 Rev.1.5
keys to set the desired values.
keys to set the mL drawn that
This menu allows to set the units of measurement of the
pump's flow rate.
The units of measure L/h e mL/min are active only after the
calibration.
Press the
Press the
key to select the desired entry.
SETTINGS AND CALIBRATION
keys to scroll the menu entries..
ENGLISH
35/100