Single-sensor mode (F1)
The single-sensor mode is activated at the factory. For changing this setting:
see "Activating two-sensor operation" on page 37.
In single-sensor mode, the sauna control unit is operated only with the heater sen-
sor with overheat cut-out (F1) only. This is included in the specifications supplied.
The sauna control unit displays the actual temperature by default. The set tem-
perature is displayed during setting. If it is to be permanently displayed it must be
activated during commissioning (see "Temperature/humidity display (actual/
set value)" on page 38)
The maximum humidity level (only Pro D3/Pro D3i) which can be set in single-
sensor mode is based on the temperature above the heater and the humidity
is timed. Only the set humidity level (in % of relative humidity) is shown on the
sauna control unit display. The actual humidity level in the sauna room when
humidity is timed depends on the size of the room and the evaporator capacity,
and may differ from the set level.
Two-sensor mode with bench sensor (F2)
Two-sensor mode must be activated using the function selection switch
(see "Activating two-sensor operation" on page 37).
In two-sensor operation with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna control unit displays
the temperature measured by the bench sensor as the actual temperature.
In two-sensor mode with bench sensor, the humidity (only Pro D3/Pro D3i) is
timed. Only the set value for the humidity level (in % of relative humidity) is dis-
played by the sauna control unit. The actual humidity level in the sauna room
when humidity is timed depends on the size of the room and the evaporator
capacity, and may differ from the set level.