Installation instructions, for professionals only
Activating evaporator single mode (only Pro D3/Pro D3i)
The evaporator is factory set so that it can only be operated together with the
heating system. To operate the evaporator on its own without the heating system,
this function must be activated. Perform the following steps:
1. Open the technician menu (see Page 39).
2. Select "SIU" by pressing the mode button D.
3. Press the On/Off button A.
4. Select the desired setting using the plus button B and the minus button C.
● "oFF" means evaporator single mode is deactivated (standard)
● "on" means evaporator single mode is activated
5. Confirm the selection by pressing the On/Off button A.
6. Make other settings or leave the technician menu by pressing the On/Off
button A for about 3 seconds.
7. Then switch the power unit off for about 10 seconds.
Activating/deactivating foil sensor (only Pro D2i/Pro D3i)
If an infra-red heater panel is connected to an additional output, the 1-014-445/
P-ISX-FF foil sensor must be used. The foil sensor must be activated. Perform
the following steps:
1. Open the technician menu (see Page 39).
2. Select "FS" by pressing the mode button D.
3. Press the On/Off button A.
4. Select the desired value with the plus button B and the minus button C.
● "oFF" means that the foil sensor is deactivated (standard)
● "on" means that the foil sensor is activated
5. Confirm the selection by pressing the On/Off button A.
6. Make other settings or leave the technician menu by pressing the On/Off
button A for about 3 seconds.
7. Then switch the power unit off for about 10 seconds.