Appliance Shutdown; Appliance Handover; Recommissioning; Maintenance And Cleaning - Stiebel Eltron WWS 20 Manuel D'utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION

Appliance shutdown

f Open the shut-off valves and hot water draw-off point.
f
f Fill the DHW cylinder.
f
f Close the shut-off valve downstream of the DHW outlet of the
f
appliance.
11.1.2 System venting
1
2
1 Fitting on the cold water inlet
2 Cold water inlet
3 Fitting on the DHW outlet
4 DHW outlet
f Leave the fitting on the DHW outlet open long enough for the
f
water to drain off free of bubbles.
f Open the shut-off valve downstream of the DHW outlet of the
f
appliance.
Note
Failure to observe the above procedure means that the
appliance cannot be guaranteed to run smoothly due to
air in the system.
Note
Observe the information in the operating and installation
instructions for the DHW cylinder.
11.1.3 Settings / function check
f To check the function, select the maximum set temperature.
f
Following completion of the function check, reduce the set tem-
perature for a more energy-conscious appliance operation.
Establish the customer's comfort requirements and select the
appropriate set temperature. For information regarding DHW
demand, consult VDI guideline 2067.

11.1.4 Appliance handover

f Explain the appliance function to users and familiarise them
f
with its operation.
f Make the user aware of potential dangers, especially the risk
f
of scalding.
56
| WWS 20
3
4
f Make users aware of critical environmental factors and re-
f
quirements concerning the installation site.
f Inform users that water may drip from the safety valve dur-
f
ing the heat-up process.
f Hand over these operating and installation instructions to
f
users for safekeeping.

11.2 Recommissioning

If the appliance is switched off due to an interruption to the power
supply, no specific measures for restarting are required once the
power supply has been restored. The appliance has saved the
parameters most recently set and continues operating with these.
Note
f Following a prolonged interruption to the power
f
supply, you must reset the time and the time pro-
gram for automatic mode.
12. Appliance shutdown
Material losses
!
The internal primary pump should be started periodically
(every 20 hours for 3 seconds) to prevent it seizing up.
f Never interrupt the power supply to the appliance.
f
f To switch off the appliance (standby mode), keep the
f
power button pressed for approx. 2 seconds.
f To switch the appliance into standby mode, keep the power
f
button pressed for approx. 2 seconds.
The appliance can only be switched off by interrupting the power
supply.
f Pull the mains plug from the socket or disconnect the appli-
f
ance from the mains at the MCB/fuse in the fuse box.

13. Maintenance and cleaning

WARNING Electrocution
Disconnect the power supply before carrying out any
work on the appliance.

13.1 Removing the casing

1 Fixing screws on casing ring
1
www.stiebel-eltron.com