OPERATION

Menu structure

MENU
Menu key
OK
OK button
Up button
Down button
f Press the Back button to go from one menu level to the high-
f
er menu level.
4.1

Switching on heat pump

f Keep the power button pressed for 2 seconds.
f
The standard display appears.
4.2

Standard display

When you are not navigating through the menu structure, the
standard display will be shown. The standard display shows the
actual temperature inside the DHW cylinder (control sensor F1)
and the current operating state of the appliance.
1
1 Operating state
2 Temperature inside the DHW cylinder
Note
While you are in the standard display, the Up and Down
buttons function like short-cut buttons to call up the cur-
rent set DHW value and, if display sensor F2 is connected,
the current actual temperature in the DHW cylinder.
4.3

DHW heating

The water in the DHW cylinder is heated up if:
- There is a current demand for domestic hot water
- DHW heating is not blocked by the time program
There is a current demand for domestic hot water when the water
temperature in the DHW cylinder is 5 K lower than the selected
set DHW value.
4.3.1 DHW mode selection
The appliance features two different operating modes for DHW
heating:
- Automatic mode
- Quick heat-up
In automatic mode, DHW heating is controlled via an individually
adjustable time program. The DHW is heated using all the heat
sources which are enabled for automatic mode (see chapter "Pa-
rameter level / Parameter setting").
In quick heat-up mode, the water is heated immediately to the
selected set DHW value, irrespective of automatic mode. Once the
selected set DHW value has been reached, the appliance switches
back to automatic mode.
www.stiebel-eltron.com
DHW heating mode setting
You are in the standard display.
f Press the Menu button.
f
The DHW heating submenu appears.
f Press the OK button.
f
The DHW mode selection submenu appears.
2
f Press the OK button.
f
The operating mode flashes.
f Set the required operating mode using the Up/Down buttons.
f
f Confirm your entry with the OK button.
f
f Keep pressing the Back button to return to the standard
f
display.
Automatic mode time program setting
Symbol
Example: DHW heating is blocked between 06:00-18:00
1 DHW heating enabled
2 DHW heating blocked
Quick heat-up activation and setting
Symbol Parameter Description
PSEt
└ SEt
Note
Automatic mode is the default factory setting.
Parameter Description
on
DHW start time:
The time when DHW heating is enabled (factory
setting = 00:00)
off
DHW stop time:
The time when DHW heating is blocked (factory
setting = 23:59)
2
1
FASt
Once-only quick heat-up starts as soon as "FASt" is
set.
b03
Select the heat source for quick heat-up
0 = Heat pump only (factory setting)
1 = Heat pump and immersion heater
WWS 20 |