Instructions for installation and use

Setting ranges

Temperature:
Humidity:
The maximum humidity level which can be set depends on the temperature of
the sauna. The higher the sauna temperature, the lower the maximum humidity
level which can be set.
Thermal safety
Heater sensor with excess temperature fuse (139 °C shut-off temperature)
Adjustable automatic heating period (6 h, 12 h, 18 h, 24 h)*
Optional single-sensor mode or two-sensor mode

Connection cables

Power supply cable:
Heater supply cable (temperature-resistant up to 150 °C): min 2.5 mm²
Sensor wires (temperature-resistant up to 150 °C):
Light wire:
Fan wire:
* EN 60335-2-53 specifies a heating time limitation of 6 h for saunas for private
use. For saunas in hotels, apartment blocks and similar locations, a maximum
heating period limit of 12 hours is permissible. Extending the heating period
limit to 18 hours or 24 hours is only permitted in public saunas.
p. 54/54
30 °C to 110 °C
0 % to 100 %
min. 5 x 2.5 mm²
min 0.5 mm²
min. 1.5 mm²
min. 1.5 mm²