Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem
Possible cause
The air conditio-
A window or door in
ner works, but
the room is open.
does not cool
There are heat sources
the air.
(lamps, etc.) turned on
in the room.
The duct is clogged or
disconnected.
The temperature is set
too high.
The air filters are
blocked with dust.
The air condi-
The air-conditioner
tioner makes a
is on an uneven or
lot of noise or
inclined surface.
vibrates.
The air conditio-
The sound is coming
ner makes gurg-
from refrigerant in the
ling sounds.
refrigerant circuit.
The air conditio-
The protective turn-off
ner turns off in
function is activated
heating mode.
automatically when
the air conditioner
overheats (when the
discharge air tempera-
ture exceeds 70°C.

ACCESSORIES

Duct (included in the set); adapter B
(rounded or oval, depending on the
model); sliding panel for placing the
duct in a window (*)
Adapter B (rounded) (*)
Wall outlet adapter A (*)
Screws and anchors (*)
Gaskets (*)
All manuals and user guides at all-guides.com
What to do
Close all windows and
doors in the room.
Turn off the heat
source.
Check the connection
of the duct and clear
all debris from it.
Decrease the set tem-
perature.
Clean the air filters.
Place the air conditio-
ner in accordance with
the requirements of
this manual.
This is normal.
Turn the air conditioner
on and wait a while
until it cools down.
1 set
1 set
1 pc.
4 pc.
3 pc.
Remote control and batteries
Drain hose
* Additional accessories, optional, not for all models.
note
After unpacking the air conditioner, make sure you have all the accessories
listed in the specifications for your model.
SPECIFICATIONS
Model
S-009
Power supply
220–240 V~ 50 Hz
Capacity
9000 Btu/h
Input
1015 W
Capacity
4800 Btu/h
Input
1400 W
Dehumidifying
1 L/h
Max. current
6.2 A
Starting current
21.7 A
Refrigerant type
R410A
Design pressure
4.2/1.5 MPa
Indoor air flow
500 m
/h
3
Indoor noise level
57 dB(A)
Operation temp
17–30 °C
Dimension (WxDxH)
465x360x750 mm
Net/Gross weight
30/33.5 Kg
The air conditioner may not function properly outside this temperature range:
Operation
Cooling
Drying (dehumidification)
Heating (type: electric heater)
NOTE
The air conditioner may not function properly outside this temperature
range.
The manufacturer reserves the right to make changes to the specifications.
INSTALLATION
Tools for installing the duct in a window
1. Screwdriver
2. Tape measure or ruler
1 set
1 pc.
S-012
220–240 V~ 50 Hz
12000 Btu/h
1380 W
4800 Btu/h
1400 W
1.2 L/h
7.4 A
22.2 A
R410A
4.2/1.5 MPa
450 m
/h
3
57 dB(A)
17–30 °C
465x360x750 mm
32.5/36 Kg
Room temperature
17°C ~30°C
13°C ~30°C
≤ 30°C