Winkhaus panicLock AP4 Série Instructions D'installation page 87

Masquer les pouces Voir aussi pour panicLock AP4 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installation, Operating and
Maintenance Instructions
a) The closure may be equipped with a maximum of two additional bolt
locks.
b) If the cylinder (PZ, RZ) standard or half-cylinder is the escape door
function of the lock is only guaranteed when the key is removed.
c) All locking cylinders with proof of suitability according to the FZG Test
Guideline Gütegemeinschaft locks and fittings e. V. as well as "profile
cylinder in accordance with EN 1303 (corrosion resistance class 3)
generally with cam position ± 30°" may be used without further proof.
Mechatronic cylinder only as specified by the manufacturer.
5.2.1 Push bar
No. Type no.
1
FSB 7980, 47°
2
ECO EPN 900 III,
47°
3
ECO EPN 900 IV,
47°
Note: The push bar must have an angle of rotation of 47°!
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49  369  3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
panicLock AP4 + AV3 OR
Codification Centre
distance
DO 20.3
92 mm PZ
94 mm RZ
DO 30.03
92 mm PZ
94 mm RZ
DO 30.03
92 mm PZ
94 mm RZ
37
Rod
Handhold
length
≤ 1150 mm
UG
≤ 1350 mm
UG
≤ 1350 mm
UG
5051068
EN
5
stainless
steel,
aluminium
stainless
steel,
steel
stainless
steel,
steel