Winkhaus panicLock AP4 Série Instructions D'installation page 67

Masquer les pouces Voir aussi pour panicLock AP4 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installation, Operating and
Maintenance Instructions
3)
The locking system is only suited for the installation of a door furniture
set with alternate function / with split handle pin. Do not apply force when
installing the handle pin.
4)
The doors must be checked to ensure that they have been installed
properly (e.g. correct air gap and alignment, residual air gap between lock
and keep – single sash 4 ± 2 mm, double sash 4 + 2 mm) and do not show
any distortion.
5)
If security door locking systems, lock plates, sealing and door closing units
are used, they are to be installed by taking their intended function into
consideration (maximum release power of 70 N) on the handle.
The maximum possible unlocking forces (release forces) are ensured via
the adjustment of the latch bolt operation, not via the adjustment of the
hooks. The hooks must run freely into the lock plate.
6)
The panicLock STV-AP4 E1 / B1 / D1 locks are to be used for single sash
doors or the master door of double sash doors with stationary slave door;
STV-AP4 E2 / B2 / D2 are to be used for the master door of double sash
doors; STV-AP4 "TE" are to be used for the slave door of double sash
doors.
7)
Fixation material for different doors (made of wood, plastics or metal):
Lock and lock plates: screws of max. 4 x ... mm (length depending on the
door system);
Door furniture set: See the installation instructions of the furniture set
manufacturer.
8)
The furniture set should normally be installed at a height of between 900
mm and 1100 mm above the surface of the finished floor with the door
closed (analog specification of EN 179 / 1125).
9)
Other closing units than the ones described in the standard can not be
installed for keeping the door closed in locked position, if the written
consent of the competent authority has not been obtained.
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49  369  3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes