Recommended Vent Length
A 3
/
" x 10" (8.3 cm x 25.4 cm) rectangular or 6" (15.2 cm)
1
4
round vent should be used.
The total length of the vent system including straight vent,
elbow(s), transitions, and wall or roof caps must not exceed
the equivalent of 140 ft (42.7 m) for either type of vent.
See the "Recommended Standard Fittings" section for
equivalent lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the
equivalent lengths of each vent piece used in the system.
See the following examples:
3
/
" x 10" (8.3 cm x 25.4 cm) vent system = 73 ft
1
4
(22.2 m) total:
A
2 ft
(0.6 m)
A. One 3
/
" x 10" (8.3 cm x 25.4 cm) 90° elbow = 25 ft (7.6 m)
1
4
B. 1 wall cap = 40 ft (12.2 m)
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
Call your authorized dealer or service center. When you call, you
will need the microwave oven model number and serial number.
Both numbers can be found on the model and serial number
plate which is located behind the microwave oven door on the
front frame of the microwave oven.
If you need additional assistance, call us at our toll-free number
or visit our website listed in the User Guide.

Replacement Parts

If any of the installation hardware needs to be replaced, call us
at our toll-free number listed in the User Guide.
Following is a list of available replacement parts. You will need
your model number located on the front facing of the microwave
oven opening behind the door.
Damper Assembly
Mounting Plate
Upper Cabinet Template
Mounting Screw Kit (includes parts A through G in "Parts
Supplied" in the "Tools and Parts" section)
B
6 ft (1.8 m)
C

ASSISTANCE

6" (15.2 cm) vent system = 73 ft (22.2 m) total:
A
2 ft
(0.6 m)
C
A. Two 90° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 m)
C. 1 rectangular to round transition piece = 5 ft (1.5 m)
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
If the existing vent is round, a rectangular to round transition
piece must be used. In addition, a rectangular 3" (7.6 cm)
extension vent between the damper assembly and rectangular
to round transition piece must be installed to keep the damper
from sticking.

Accessories

Filler Panel Kits are available from your dealer to use
when installing this microwave oven in a 36" (91.4 cm)
or 42" (106.7 cm) wide opening. The filler panels come
in pairs. Each panel is 3" (7.6 cm) wide.
A. Filler panels
Filler Panel Kits:
See your authorized dealer or service center for details.
B
6 ft (1.8 m)
D
A
8171336
White
8171337
Black
8171338
Biscuit
8171339
Stainless Steel
99403