Led Illuminator Switching On Threshold Adjustment; Led Illuminator Power Adjustment - Videotec ULISSE Manuel D'instructions

Masquer les pouces Voir aussi pour ULISSE:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 118
8.10.5 LED illuminator switching on
threshold adjustment
The illuminator on the right must always be
set to maximum brightness.
Switch-on threshold
regulator
Fig. 39
The illuminator has an integrated twilight sensor that
allows its automatic activation and deactivation at
predefined luminous conditions.
The twilight sensor is set in the factory at a
predetermined luminous level, suitable for most
installations (approximately 50lx). If you want to
adjust in different ways the threshold, loosen the
plug on the illuminator rear and proceed for the
adjustment with a screwdriver.
By rotating the trimmer clockwise, the night mode
changeover is anticipated (at a greater luminous
value). By rotating the trimmer anti-clockwise,
the night mode changeover is delayed (at a lower
luminous value).
MIN
OFF
Fig. 40
Wait for appropriate brightness before switching on
the illuminator. Rotate the trimmer slowly until the
LED on the side of the trimmer switches on. Once the
intervention threshold has been surpassed (LED on),
rotate it slightly in the opposite direction.
After making the adjustments make sure
that the plug is closed tight to ensure
perfect sealing.
28
MAX
8.10.6 LED illuminator power
adjustment
The illuminator on the right must always be
set to minimum power.
The illuminator is set in the factory to
provide maximum power. If you don't
need to illuminate distant subjects or if
the image is over-exposed for excessive
brightness, decrease the power, so that
energy saving is also obtained.
Fig. 41
Loosen the hermetic plug. Rotate the trimmer,
clockwise to increase the power of the infrared
illuminators and anti-clockwise to decrease it.
MIN POWER
Fig. 42
After making the adjustments make sure
that the plug is closed tight to ensure
perfect sealing.
Infrared power
control
MAX POWER
MNVCUPT3_1511_EN

Publicité

Table des Matières
loading

Table des Matières