Overview; Included; Installation - Resol KM1 Manuel

Module de communication
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1

Overview

• With VBus.net support
• Comfortable system parameterisation via the RESOL ServiceCenter
software or the RESOL RPT parameterisation tool
• Quick error diagnostics
• Suitable for all RESOL controllers with VBus
• Integrated LAN connector for network connection
Technical data
Housing: plastic, PC-ABS and PMMA
Protection type: IP 20 / EN 60529
Protection class: III
Ambient temperature: 0 ... 40 °C
Dimensions: Ø130 mm, depth 45 mm
Mounting: wall mounting
Display: operating control LED
Interfaces: RESOL VBus
for the connection to the controller, 10/100 Base TX
®
Ethernet, Auto MDIX
Power consumption: < 1,95 W
Power supply: input voltage of mains adapter: 100 ... 240 V~ (50 ... 60 Hz)
nominal current: 350 mA
input voltage of communication module: > 5 V DC ± 5 %
20
®
45
Drill hole positions
2

Included

If one of the items mentioned below is missing or defective, please contact your
distributor:
1
KM1 Communication module, mains adapter and VBus
2
Interchangeable mains adapter plugs (EURO, UK, USA, AUS)
3
Network cable (CAT5e, RJ45), 2 m
4
Wall plugs and screws
5
Terminal block for extending the VBus
Manual
3

Installation

ATTENTION!
ESD damage!
Electrostatic discharge can lead to damage to electronic com-
ponents!
Î Take care to discharge properly before touching the
inside of the device. To do so, touch a grounded sur-
face such as a radiator or tap!
The KM1 Communication module comes with mains adapter and VBus
ready connected to the device.
The housing does not have to be opened in order to mount the device.
Initial installation must be effected by the system installer or qualified personnel
named by the system installer.
®
cable pre-connected
cable
®
cable al-
®

Publicité