Batteries: Preparation; Batteries: Installation And Connection - Dustbane Hurricane 400 Manuel D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Batteries: preparation

! DANGER: During battery installation and any type of battery maintenance, the operator must be provided with the necessary personal
protection devices (gloves, goggles overalls, etc.) to limit the risk of injury. Keep clear of naked flames, avoid short circuiting the battery
poles, avoid sparks and do not smoke.
Batteries (WET) are normally supplied filled with acid and ready for use.
If the batteries are wet, proceed as follows before installing them in the machine:
• Remove the caps and fill all elements with sulfuric acid solution specific for batteries until the plates are entirely covered
(this requires at least a couple of refills for each element). IF IN DOUBT, CONTACT THE DEALER.
• Leave the batteries stand for 4-5 hours to allow air bubbles to come to the surface and the plates to absorb the
electrolyte.
• Make sure the level of electrolyte is still above the plates and if necessary top up with sulfuric acid solution.
• Close the caps.
• Install the batteries in the machine (following the procedure described below).
• Charge the batteries before starting up the machine for the first time. Follow the instructions in the "Battery maintenance
and charging" section.

Batteries: installation and connection

! INFORMATION: Batteries must only be installed and connected by qualified technical personnel.
! DANGER: Remove the electronic key from the instrument panel before installing and connecting the batteries. Make sure you connect
the terminals marked with a "+" to the positive poles of the battery. Do not check the battery charge by sparking.
Meticulously follow the instructions given below as short circuiting the batteries could cause them to explode.
• Make sure the two tanks are empty (if necessary, empty them. See the relevant paragraph).
• Release the recovery tank (ref. 1) from the solution tank by pulling the catch. Tilt the recovery tank all the way back to
provide access to the battery compartment.
• Place the batteries in the compartment in the direction shown in the drawing printed inside
the compartment on the solution tank.
• Referring to the wiring layout, connect the battery cable and bridge terminals to the battery poles. Arrange the cables as
shown in the diagram, tighten the terminals on the poles and cover with Vaseline.
• Lower the recovery tank. Make sure it latches properly with the solution tank;
! WARNING: Never allow the batteries to become excessively flat as this could damage them irreparably.