Motion Off behaviour ( timeout ):
Parameter Number
16 ( MOTION_DISABLE )
Motion disable timeout after BASIC SET to motion endpoint when the internal
motion sensor is not used for evaluating the behaviour of the LED and groups 2
and 3. Events are, however, still transmitted to the Lifeline, and the device can be
controlled via remote motion sensors.
0
BASIC SET to Motion sensor endpoint ignored, BASIC to root is
mapped to LED endpoint, motion sensor still enabled
1 – 209
Internal motion sensor is disabled for specified timeout after BASIC
SET 0x00 to Motion sensor endpoint. BASIC to root is mapped to
Motion sensor endpoint.
Timeout:
1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in 1-second resolution
101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) in 1-minute
resolution
201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour resolution
210 – 254
Reserved
255
BASIC SET to Motion sensor endpoint ignored, BASIC to root is
mapped to LED endpoint, motion sensor still disabled
Toggle button behaviour:
Parameter Number
17 ( BUTTON_BEHAVIOUR )
Bit Field:
Bit
7
6
5
4
Function -
-
-
Dim
disable
Dim increase ( bit 0 ):
- long press of button does dim decreasing ( 0 = default )
- long press of button does dim increasing ( 1 )
Scene switch ( bit 1 ):
- short press of button does toggle – on/off ( 0 = default )
- short press of button does scene switch ( 1 )
Size
Range
Default
2
0 – 209, 255
0
( SPIR )
Size
Range
Default
1
0 – 15
8
3
2
1
0
Network
Standa-
Scene
Dim
bahaviour
lone
switch
increase
bahaviour
behaviour
- 42 -
Standalone behaviour ( bit 2 ):
- using "legacy" sensor deactivity after button press ( 0 = default )
- using "cfg 10-14" sensor deactivity after button press ( 1 )
Network behaviour ( bit 3 ):
- using "legacy" sensor deactivity after button press ( 0 )
- using "cfg 10-14" sensor deactivity after button press ( 1 = default )
Dim disable ( bit 4 ):
- dim events ( long press ) are used ( 0 = default )
- dim events ( long press ) are ignored ( 1 )
"legacy" sensor deactivity behaviour does this:
- Pressing push button when LED is OFF: LED will switch on as long as there is
movement and the delay time runs of
- Pressing push button when LED is ON: LED will switch off as long as there is
movement ans the delay time runs of ( invers logic ).
"cfg 10-14" sensor deactivity behaviour uses behaviour specified in parameters
10-14 ( the same behaviour as pressing of external switch using BASIC ON/OFF
functions )
Toggle button Scene 1-4:
Parameter Number
18 ( BUTTON_SCENES )
Parameters 18 specifies scene numbers ( from 1 to number ) to be switched by
toggle button. 0 menas – do not useany.
Toggle button inactivity time in "legacy" mode ( timeout ):
Parameter Number
19 ( LEGACY_INACTIVITY_TIME )
In "legacy" button mode function this timeout is used to cancel motion sensor
inactivity mode after motion end ( both for on and off state of LED ).
1 – 209
Timeout:
1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in 1-second resolution
101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) in 1-minute resolution
201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour resolution
0,210 – 254 Reserved
Size
Range
Default
1
0, or 1 – 127
1
Size
Range
Default
2
1 – 209
103