STEINEL MotionSwitch LED Z-Wave Mode D'emploi page 18

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

For parameter 16 = 0 or 255:
Basic Set: mapped to Binary Switch Set of LED endpoint
Basic Get: mapped to Binary Switch Get of LED endpoint
Basic Report: mapped to Binary Switch Report of LED endpoint
For parameter 16 = 1-204:
Basic Set: active ( 0xFF ) /inactive ( 0x00 ) sensor function
Basic Get: request sensor status
Basic Report: advertise sensor status
1 = MOTION SENSOR
To endpoint 1 is mapped motion sensor ( PIR ) functionality.
Device type = Sensor - Notification
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
COMMAND_CLASS_NOTIFICATION ( V4 )
COMMAND_CLASS_SUPERVISION ( v1 )
Controlled Command Classes:
COMMAND_CLASS_BASIC ( v1 )
Special meaning of BASIC CC:
BASIC CC can activate/temporary deactivate internal motion sensor
using for evaluating the behaviour of the LED and groups 2 and 3.
Events are, however, still transmitted to the Lifeline, and the device
can be controlled via remote motion sensors ( please also follow the
configuration parameter 16 ).
Basic Set: active ( 0xFF ) /inactive ( 0x00 ) sensor function
Basic Get: get sensor activity
Basic Report: sensor activity status
2 = AMBIENT LIGHT SENSOR
To endpoint 2 is mapped ambient light sensor functionality.
Device type = Sensor - Multilevel
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_SENSOR_MULTILEVEL ( v4 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
COMMAND_CLASS_SUPERVISION ( v1 )
Controlled Command Classes:
No
- 34 -
3 = LED
To endpoint 3 is mapped basic LED functionality.
Device type = On/Off Power Switch
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_BASIC ( v1 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
COMMAND_CLASS_SWITCH_BINARY ( v1 )
COMMAND_CLASS_SWITCH_ALL ( v1 )
COMMAND_CLASS_APPLICATION_STATUS ( v1 )
COMMAND_CLASS_SUPERVISION ( v1 )
Controlled Command Classes:
No
4 = BUTTON
To endpoint 4 is mapped button functionality.
Device type = Wall Controller
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_CENTRAL_SCENE ( v1 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
COMMAND_CLASS_SUPERVISION ( v1 )
Controlled Command Classes:
COMMAND_CLASS_BASIC ( v1 )
COMMAND_CLASS_SWITCH_MULTILEVEL ( v4 )
COMMAND_CLASS_SCENE_ACTIVATION ( v1 )
B� Description of association groups:
0 = ROOT DEVICE
Group 1 – "Lifeline" – only 1 node
Lifeline messages
- Device Reset Locally
- Notifications:
0x07 ( Home security ) – Motion Begin event ( 0x08 )
0x07 ( Home security ) – Motion End event ( 0x00, 0x08 )
- Binary Switch Report – LED state
- Multilevel Sensor Report – value of internal ambient light sensor
- Central scene notification – button events
- 35 -

Publicité

Table des Matières
loading