13.2
DSP-EM
If the system detects an error, it switches off independently. The toolbar and the dis-
play bar are hidden.
Error
Source
code
DSP
E-01
E-02
E-03
E-04
–E-05
E-06
E-07
E-09
E-10
E-11
E-12
Display
E-16
E-18
E-20
EN
Possible cause
Battery undervoltage
Battery overload
Inverter overload
Overheating of device
Initialisation error
Uninterrupted power
supply is not present
Under-temperature
Overheating of battery
Grid input overcurrent
Overvoltage battery
CI bus does not respond
DSP-C does not respond Set the main switch to REMO.
Battery charging status
too low
Troubleshooting
Possible Solution
Charge the battery.
Reduce the input voltage.
Reduce the connected load.
Ensure sufficient air supply at the
device.
Contact customer service.
Activate the inverter function (chapter
"Switching the inverter function on/
off" on page 25).
Check the connection to the mains
power supply.
Contact customer service.
Ensure sufficient air supply at the
battery.
Contact customer service.
Contact customer service.
Check the BUS cabling of the battery
sensor.
Check the BUS cabling of the DSP-C
device.
Charge the battery.