Example (values for illustration purpose only):
AC OUTPUT
I
NOTE
Keep in mind that the device only measures the current which flows
through the device. If you connect more consumers in parallel, e. g.a
refridgerator or an separate charger, this additional load may trip the
fuse. In this case, set the power sharing level value below the fuse's value
accordingly.
Generator function (external mains power supply)
A
NOTICE!
Observe the standards that apply in your country to the generator
function.
If the load current is greater than the fuse of the connected 230 V power source, the
fuse would normally blow. The generator function enables the device to provide
additional power, which it takes from the battery.
If the required power falls below the power sharing level, the device recharges the
battery.
In generator mode, the 230 V power source and the battery act as a common power
source. While doing so, the battery is discharged.
The generator mode can manually be shut off via DSP-EM to ensure that the battery
will not be discharged.
If the battery's voltage or capacity does not suffice to support the grid the device is
disconnected from the grid and the inverter tries to work in isolated operation.
EN
BR
EA
KE
R
OU
TP UT
8 A
IN PU
T
10 A
AC INPUT
230 V
Technical description
2 A
12/24 V
13