Cleaning and maintenance
26/46
Push the pins vertically into the socket from above.
Turn the lamp 90°.
The lettering must be oriented towards the outside (i.e. towards the tan-
ning room or towards the user).
4.9.2

Starter

Replace faulty starters immediately.
You can recognise a faulty starter by the blackened ends of the UV low pres-
sure lamps or when the UV low pressure lamps can no longer be started.
Operating a UV low pressure lamp with a faulty starter significantly shortens
its service life. The UV low pressure lamp loses power and may begin to flick-
er under certain circumstances.
The starters are located in either one of the two lamp sockets or are visible
when the UV low pressure lamps are removed.
Turn 90° and carefully remove from the socket.