Current Measurement - VOLTCRAFT VC 505 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

f) Current measurement
always hold only one conductor with the current injection probe. holding
several conductors will not give you a measuring result.
Due to the sensitivity of the current sensor, a low current may be shown on
the LCD display during the voltage measurement even if no conductor is
involved.
DC zero adjustment may only be carried out, when the conductor is inserted
between the jaws.
manually set the displayed value to zero by pushing the button "8" for at
least 2 seconds. the LC display shows the value "zEro" (only possible and
required for DC measurement).
• If present, remove the measuring lines from the meter before measuring current.
• Select the function for current measurement
• Open the probe sensor "1" with the opening lever "5", hold the conductor to be measured
and close the probe sensor "1" again.
• The measured current is indicated on the LC display.
• Take the probe sensor "1" from the conductor again after measurement and switch off the
meter. For this, turn the adjustment wheel "6" into the position "OFF".
or
with the adjustment wheel "6".
31

Publicité

Table des Matières
loading

Table des Matières