AHT Cooling Systems GmbH | en
Destruction of the coating and consequent impairment
of the function.
§ Do not hold the door open using your body or ob-
jects.
d) Remove food and packaging residues.
e) Remove soiling and ice from the seals. Clean the
seal from top to bottom.
1
Fig. 15: Seal cleaning
f) Clean the floor around the appliance
NOTICE
Property damage due to misuse.
§ Only add goods to the appliance once the spe-
cified temperature for the product has been
reached.
g) Check the temperature display on the interior ther-
mometer [see } Chapter 5.1].

11.1.2 Main cleaning

The main cleaning is an intensive cleaning procedure.
Responsibility
– Only cleaning companies or qualified staff au-
thorised and trained by AHT may carry out a main
cleaning [see } Chapter 11.1.2].
Cleaning interval
– At least once a year, or
– according to separate maintenance agreement
between AHT and customer.
More information [see } Chapter 3.4]
Cleaning steps
Follow the cleaning instructions.
These instructions are available from qualified staff
and cleaning companies authorised by AHT.
12
Maintenance, service and
repairs
Only qualified staff may carry out maintenance, ser-
vice, and repair work, including the following functional
test.
In the event of questions relating to maintenance, con-
tact the maintenance service [see } Chapter 12.5].
428175_1_0121

Maintenance, service and repairs | 12

WARNING
Work on the electrical system and re-
frigerant circuit.
Contact with live parts may result in electric
shock. Flammable refrigerant can escape and
cause an explosive gas/air mixture. Com-
pressor oil can leak out during repairs. Fire
hazard due to sparking or overload.
§ Only qualified staff may carry out work on
the electrical system and refrigerant cir-
cuit.
§ Observe the electrical safety rules prior to
commencing work.
1. Disconnect the appliance.
2. Secure the appliance against reconnec-
tion.
§ Observe the specific safety instructions
[see } Chapter 2.5.2]
§ During the repair, a competent person
with knowledge of local conditions must
be available as contact for the qualified
staff.
§ Only qualified staff may restart the appli-
ance and perform functional tests.
CAUTION
Sharp edges, rotating parts. Hot sur-
faces.
Risk of injury to hand and body. Risk of burns
in the event of skin contact.
§ Only qualified staff may carry out mainten-
ance service repairs on the appliance.
§ Wear protective gloves.
§ Do not touch hot surfaces, in particular
compressors, condensers and hot gas
lines, until they have cooled down.
12.1
Maintenance
Maintenance interval
– Once a year
– or according to separate maintenance agreement
between AHT and customer
Perform maintenance
Observe maintenance instructions and maintenance
logs. These are available from qualified staff.
12.2

Replacing lights

Lights used
– LED bars
Technical data [see } Chapter 3.2]
a) If a light fails, contact the maintenance service.