3

Product description

3.1

General information

AHT products comply with EU Regulation 1907/2006
(REACH) on the Registration, Evaluation, Authorisa-
tion and Restriction of Chemicals.
3.2

Technical data

Important technical data can be found on the power
rating plate [see } Chapter 3.2.1].
Parameter
Value
See →Appliance model over-
External dimensions
view
See →Appliance model over-
Appliance weight
view
Refrigerant
Propane (R-290)
Refrigerant per refri-
≤ 150 g
gerant circuit
Ozone depletion po-
tential (ODP)
0
Propane (R-290)
Global Warming Po-
tential (GWP)
3
Propane (R-290)
Airborne noise emit-
ted/emission sound
< 70 dB(A)
pressure level
Maximum load
Parameter
Value
Sticker at the top right of the in-
Storage racks, Load-
side of the equipment cover
ing specification
next to the power rating plate
Display shelf
115 kg/m²
Bottom shelf
600 kg/m²
Mesh basket/pieces 80 kg
Recommended light colours
Parameter
Value
Neutral white
4000 K
Cold white
5000 K
Ultra cool white
6500 K
Technical interfaces
Defrosting water
DN 40
drain
Brine connection
3/4ʺ
Conical fitting
(flow and return)
Bus system
Bus system
AHT Inter Cabinet BUS (ICB)
(Communication)
CAT 5-S/FTP (PIN 1 ... 8 as-
Bus cable
signed) RJ45
428175_1_0121
Electrical connection
rated voltage
3N 380 – 420 V
rated frequency
50 Hz
Plug types
CEE 5 x 16 A
5-pin cable with protective con-
Connecting cable
ductor (PE) and neutral con-
ductor (N)
Minimum cross-sec-
tion for connecting
2.5 mm²
cables
Floating contact via market light
signal box (accessory)
Light control
The control signal for the mar-
control of external
ket light signal box must be
day/night signal
coupled with an isolation trans-
former to the market lighting
separated from the mains
Fusing
[see } Chapter 8.2]
Rated
Fault
Type
cur-
cur-
rent
rent
[A]
[mA]
Circuit breaker (LS/CB)
16
-
-
Residual current circuit breaker (FI/RCCB/GFCI)
G (short-time delay)
A (pulse current-sensit-
ive)/
40
30
F (mixed frequency-sens-
itive)/
B (universal current-sens-
itive)
Residual current circuit breaker with overcurrent pro-
tection FI-LS/RCBO (alternative to RCCB and CB)
G (short-time delay)
A (pulse current-sensit-
ive)/
16
30
F (mixed frequency-sens-
itive)/
B (universal current-sens-
itive)
Custom deviations possible.
More information: Maintenance services
[see } Chapter 12.5]
Subject to technical changes.
3.2.1

Rating plate and serial number

Observe the information on the rating plate.
The rating plate is a sticker located at the top right in-
side the appliance.
Information on rating plate
– Appliance name and type
– Serial number
Product description | 3
Tripping
charac-
teristic
C (slow-
acting)
-
C (slow-
acting)