Daily Maintenance - EdilKamin NANCY Installation, Usage Et Maintenance

Masquer les pouces Voir aussi pour NANCY:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
MAINTENANCE
Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is required for the stove to function correctly.
FAILURE TO KEEP UP REGULAR MAINTENANCE DOES NOT allow the stove to function properly.
Any problems resulting from lack of maintenance will immediately void the warranty.
TO ACCESS ALL ELECTRICALAND MECHANICAL PARTS EASILY SIMPLY OPEN THE LEFTHAND
DOOR OF THE STOVE. THE DOOR IS HELD FIRMLY SHUT WITH A SCREW, WHICH MUST ONLY BE
REMOVED FOR INSPECTION PERFORMED BY THE TECHNICALASSITANCE CENTRE.

DAILY MAINTENANCE

Operations must be performed when the stove is off, cold and unplugged from the power supply
• Must be performed using a vacuum cleaner (see optional extras page 39).
• The whole procedure takes up a few minutes every day.
• Open the righthand door, remove the combustion chamber (1 - fi g. A) and empty the residue out into the ash pan (3 - fi g. C).
• DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER.
• Take out the ceiling (2 - fi g. B) and empty the residue out into the ash pan (3 - fi g. C).
• Take out and empty the ash pan (3 - fi g. C) into a fi reproof container (the ash may still contain hot parts and/or embers).
• Remove the combustion chamber or use the spatula to scrape it and clean out any blocked holes on all sides
• Remove the combustion chamber (1 - fi g. A) and scrape with a spatula. Clean any obstructions in the apertures.
• Vacuum the combustion chamber holder, clean the edges where the combustion chamber is lodged into its seat.
• Clean the glass, if necessary (when cold).
Never vacuum hot ash, it can make the vacuum cleaner breakdown and puts the household rooms at risk of fi re
1
2
3
fi g. A
fi g. B
fi g. C
MANUTENZIONE SETTIMANALE
• Involves cleaning the hearth (with a swab) once the ash pan has been removed (3 - fi g. C).
• empty the pellet hopper and clean the base with the vacuum cleaner.
• Clean with the swabs (4 - fi g. D), vacuum out the 3 pipes below (5 - fi g. E)
• Clean out the combustion chamber and smoke extractor (6 - fi g. E).
4
6
5
fi g. D
fi g. E
- 35
-

Publicité

Table des Matières
loading

Table des Matières