General Safety Notes; Intended Use; Assembly; Function And Application - schmalz Multi-Clamp VC-M Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2
Operating Instructions for Multi-Clamp VC-M with Integrated Ejector
2.1
Safety information

General safety notes

 These operating instructions contain important
information
on
using
Multi-Clamp
clamping
system
VC-M.
operating instructions thoroughly and keep them
for later reference.
 The clamping system may only be connected and
commissioned after the operating instructions
have been read and understood.
 In addition to these operating instructions,
instructions must also be provided within the
meaning of the German "Health and Safety at
Work Act" [Arbeitsschutzgesetz] and the German
"Ordinance on Industrial Safety and Health"
[Arbeitsmittelbenutzungsverordnung].
 General
safety
regulations
standards, including those set by the machine
manufacturers, must be observed and adhered
to.
 Installation may only be carried out by qualified
specialist personnel.
 Sudden vacuum failure may lead to hazardous
situations.
 The Multi-Clamp vacuum clamping system VC-M
may only be used for the purpose for which it was
intended.
 The clamping system may only be operated in a
sound, fully-functional condition.
 Devices using compressed air can cause harm to
people and damage property.

Intended use

 The Multi-Clamp vacuum clamping system VC-M
is used for clamping flat workpieces during
manual processing. The clamping system is
attached mechanically using the threads/holes
provided in the base plate.
 The clamping system should be fixed to a solid,
secure work surface.
 The Multi-Clamp system VC-M is designed for
clamping by means of a vacuum. However, it is
only suitable for clamping flat workpieces where
the contact surface must be two-dimensional in
design.
 The clamping of highly porous or uneven
workpieces can lead to a reduction of its intended
function and must be checked by specialist
personnel.
 Air or other neutral gases as per ISO 8573-1 are
approved as media to be evacuated.
 It is not permitted to apply suction to liquids,
corrosive gases or granulates.
 An appropriate filter must be used in cases of
heavy soiling.
2.2
Initial startup
 Ensure that the clamping system is assembled
according to the description.
 Place the clamping system on a solid, secure
surface.
 Secure the clamping system to the work surface
mechanically using screws etc.
 Place the supplied suction plate on the Multi-Base
turn/swivel fixture as directed in the assembly
description and attach it using the clamping lever.
 Connect the base to the suction plate using the
short hose.
 Connect the Multi-Base to the compressed air
supply using the supplied hose set.
 If you wish to have two or more systems in use,
connect the individual systems using the VC-M
accessory set (item no.: 10.01.12.02061 and see
also section 2.7).
 The system is now ready for use.
2.3
Description

Assembly

vacuum
Please
read
the
1
7
8
5
and
European
2
3
No.
1
2
3
4
5
6
7
8

Function and application

The Multi-Clamp suction plate is a plate made from
plastic. It is set down on and secured to the Multi-
Base turn/swivel fixture. Ensure that the Multi-Clamp
suction plate rests fully on the Multi-Base. It locks
into the appropriate position. Compressed air (opt.
4.5 bar) is connected to item [2] using the supplied
hose set.
 The Multi-Base should be fixed with screws at
item [3] to a surface that is as firm as possible.
 Make sure that all clamping levers are released
and position the Multi-Clamp suction plate as
shown in the above illustration and close the
clamping lever (item 6).
 To connect the Multi-Base to the Multi-Clamp
suction plate, attach the supplied short hose to
the Multi-Base (item 8) and to the Multi-Clamp
suction plate (item 7).
 The Multi-Clamp suction plate is secured to the
Multi-Base with the clamping lever (item 6).
However, it can still be turned.
 The Multi-Clamp suction plate is secured against
twisting using the clamping lever (item
 The Multi-Base is secured against rotation using
the clamping lever (item 4).
 Attach compressed air (opt. 4.5 bar) to item [2]
using the supplied hose connection set. The holes
on the side of the blue body allow you to pass the
hose through the side.
 To replace the suction plate, remove the small
piece of hose from the attached plate and connect
it to the replacement plate.
 By activating the compressed air/vacuum, a
vacuum is generated on the top side of the Multi-
Clamp suction plate. This vacuum is responsible
for securing the workpiece.
Multi-Clamp VC-M
Description
Multi-Clamp suction plate VC-M-SP
Compressed air hose connection (opt. 4.5 bar)
Attachment hole
Clamping lever (swivel)
Clamping lever (turn)
Clamping lever (change suction plate)
Plug connector (angle)
Connection for suction plate base
Page 2
2.4
Clamping a workpiece
 Check the entire clamping system for visible
damage and soiling and deal with any problems
immediately.
 Check the available clamping area and the secure
positioning of the workpiece, both visually and
manually. It must not be possible for the
workpiece to easily move or detach.
 The generated machining forces must not exceed
the available clamping forces. In case of doubt,
select low operating parameters and gradually
maximize.
2.5
Cleaning and system care
6
The Multi-Clamp clamping system should be
cleaned regularly (wipe down with a damp cloth and,
if necessary, remove soiling).
4
2.6
Specifications
System
Dimensions [mm]
Weight [kg]
Pressure [bar]
3
Suction capacity [m
/h]
Air consumption [l/min]
Noise level [db(A)]
2.7
Accessories and spare parts
Type
Item no.
Foot switch
10.01.12.02055
Accessory
10.01.12.02061
set
(Y piece for
combining
two
Multi-
Clamps)
Multi-Clamp
10.01.12.01836
suction
plate VC-M-
SP 160x160
Rotation
10.01.12.01944
unit
for
endless
horizontal
rotation
of
the
workpiece
DE-50
External
diameter D:
50 mm
2.8
Troubleshooting
Problem: No vacuum
• Check the connections.
• Check the whole system for leaks.
• Check the position of the sealing cord.
• Check the sieve on the vacuum vent for dirt and
clean if necessary.
• Knot holes in the workpiece can cause leaks.
5).
• Porous workpieces are difficult to pick up (MDF
sheets, etc.).
• Ensure that the vacuum supply is secure, check
compressed air or vacuum generator.
2.9
Warranty, spare and wearing parts
This device is guaranteed in accordance with our
General Terms and Conditions of Sale and
Delivery. The same applies for spare parts,
provided that these are original parts supplied by
us.
We are not liable for any damage resulting from the
use of non-original spare parts or accessories.
Wearing parts are not covered by the warranty.
VC-M
162x162x215
4.6
4.5 – 6
2.3
48
62
Type
Item no.
Multi-Clamp
10.01.12.02002
suction plate
VC-M-SP 210
Multi-Clamp
10.01.12.02003
suction plate
VC-M-SP
200x55
Multi-Clamp
10.01.12.02052
suction plate
VC-M-SP
300x100

Publicité

Table des Matières
loading

Table des Matières