An Please read these instructions in conjunction with the appropriate 3M™ Filter Leaflet and with the 3M™ Face Piece Reference
Leaflet where you will find information on:
• Approved combinations of 3M™ filters
• Accessories
• Spare parts
SYSTEM DESCRIPTION
These products meet the requirements of EN 140:1998, re-usable half masks and should be used in combination with a pair of approved 3M filters (see
Reference Leaflet) to form a filtering apparatus for respiratory protection. These products meet the requirements of EN 140:1998, re-usable half masks
and should be used in combination with a pair of approved 3M filters (see Reference Leaflet) to form a filtering apparatus for respiratory protection. Such
apparatus is designed to remove potentially harmful particulates from the surrounding atmosphere.
^ WARNINGS AND LIMITATIONS
^ Particular attention should be given to warning statements where indicated.
^ WARNINGS
Always be sure that the complete product is:
- Suitable for the application;
- Fitted correctly;
- Worn during all periods of exposure;
- Replaced when necessary.
• Proper selection, training, use and appropriate maintenance are essential in order for the product to help protect the wearer from certain
airborne contaminants. Failure to follow all instructions on the use of these respiratory protection products and/or failure to properly wear
the complete product during all periods of exposure may adversely affect the wearer's health, lead to severe or life threatening illness or
permanent disability.
• For suitability and proper use follow local regulations, refer to all information supplied or contact an occupational hygienist, safety professional or 3M
representative on the Tech Assist Helpline 3M Australia 1800 024 464, 3M New Zealand 0800 364 357.
• Only use with the 3M™ Filters and spares and accessories listed and within the usage conditions given in the Technical Specification.
• Never modify or alter this product. Replace parts only with original 3M spare parts.
• Maintenance, servicing and repair must only be carried out by properly trained personnel.
• General inspection must be carried out before use or monthly if not in regular use. See Inspection procedures for specific details.
• Do not use in atmospheres containing less than 19.5% oxygen. (3M definition. Individual countries may apply their own limits on oxygen deficiency.
Seek advice if in doubt).
• Do not use these products in oxygen or oxygen-enriched atmospheres.
• Do not use for respiratory protection against atmospheric contaminants/concentrations which have poor warning properties or are unknown or
immediately dangerous to life and health (IDLH) or against contaminants/concentrations which generate high heats of reaction with chemical filters.
• Select and wear appropriate protection when exposed to sparks and/or flames.
• In case of intended use in explosive atmospheres, contact 3M.
^ Do not use with beards or other facial hair that may inhibit contact between the face and the product thus preventing a good seal.
• Leave the contaminated area immediately if:
a) Breathing becomes difficult or increased breathing resistance occurs.
b) Dizziness or other distress occurs.
c) You smell or taste contaminants or irritation occurs.
d) Airflow to the face piece decreases or stops.
e) Any part of the system becomes damaged.
• National regulations may impose specific limitations on the use of filters depending on the filter class and the facepiece used. Use of any 3M™ Face
piece / Filter combination should be in accordance with applicable Health and Safety standards, AS/NZS 1715, Respiratory Selection Tables or in
accordance with the recommendations of an Occupational Hygienist.
• Materials which may come into contact with the wearer's skin are not known to cause allergic reactions to the majority of individuals.
• These products do not contain components made from natural rubber latex.
PREPARATION FOR USE
UNPACKING
Inspect the package contents for shipping damage and ensure all components are present.
Check apparatus is complete, undamaged and correctly assembled
The "QL" mark on the latch identifies this facepiece as a 3M™ Half Mask 6500QLSeries.
Inspection
The following inspection procedure is recommended before use:
1. Check the face piece for cracks, tears and dirt. Be certain the face piece, especially the face seal area, is not distorted. The material must be pliable –
not stiff.
2. Examine the inhalation valves for cracks or tears. Lift valves and inspect valve seat for dirt or cracks.
3. Ensure that the head straps are intact and have good elasticity.
4. Examine all plastic parts for signs of cracks or fatigue.
5. Remove the exhalation valve cover and examine the exhalation valve and valve seat for signs of dirt, distortion, cracks or tears. Replace the
exhalation valve cover.
ASSEMBLY INSTRUCTIONS
See appropriate product user instruction (eg. 3M filter leaflet)