RF_prog:RF_prog_ACOVA_7L 22/10/2010 09:20 Page46
5. Associating your appliance
with other X2D devices
5.1 Associating the appliance with a PLC unit
Your appliance can be controlled remotely by a PLC (Powerline Carrier) program-
ming base unit using the X2D protocol (not supplied).
To enable this, you need to:
_ install and connect your appliance (section 1)
_ associate your appliance with the room thermostat (section 4.6)
_ associate your appliance with the PLC unit (not supplied)
To do this, place your programming base unit into association mode (see the
instructions supplied with the unit).
Access advanced settings menu CF05 on the room thermostat (see section 4.5).
Set the value to 1 (cycle mode disabled).
The PLC light on the appliance receiver will blink.
Then press the
EN
ting that the PLC unit association signal has been received.
Your radiator(s) is (are) now associated with your base unit.
The TH light is glowing steadily (the radiator is associated
with the thermostat) and the PLC light is blinking,
showing that it is awaiting association with the PLC unit
IMPORTANT Turn the room thermostat dial to
(
Then turn the dial to
46
button. The light will stop blinking and glow steadily, indica-
) for every hour of each of the 7 days (see section 3.3).
. The appliance will then be controlled by the PLC unit.
AUTO
The CPL light glows steadily when the association signal
from the programming base unit has been received
and set the mode to
PROG