1.3 Connecting the radiator
The technical specifications of your radiator are shown on the nameplate, which
is positioned on the side of the radiator towards the bottom.
Please take note of these before installing the radiator.
Connection to the electrical supply must be done in accordance with:
_ The voltage and power indicated on this label
_ Conventional colour coding: Brown for live, Blue or Grey for neutral.
EN
The flexible cord suplied is designed for connection to the electrical supply via a
connection box placed behind the appliance, with no need for a plug.
In a kitchen or bathroom, the connection box should be placed at least 25 cm off
the ground.
For dual-energy radiators:
You are advised to install a circuit breaker between your radiator and the
electricity supply to disconnect it from the power when it is used with your central
heating system.
1.4 Radiator installation restrictions
This appliance must be installed in accordance with applicable standards and
good practice in the country concerned.
The radiator must not be exposed to intensive or on-going ambient humidity
(shower, swimming pool, etc.).
32
IP : level of protection against ingress of water
xxxV – xxxxW : voltage and power required
for installation
Model type
Classe II : double insulation
OF : serial number