Connectors And Connections; Installation Example - Videotec PTH310 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connectors and connections

The installation must be carried out only by qualified technical staff: an improper connection of the peripheral
units may cause the keyboard to be isolated from the rest of the system.

Installation example

Installation controlled by one operator with one monitor: the operator controls one pan & tilt motor and the following
telecamera functions FOCUS, ZOOM, DIAPHRAGM (IRIS):
Installation example
One operator with more monitors, who controls a series of pan & tilt motors in mixed configuration (star and cascade
connection)
DTRX3
DTRX3
DCS2
7 wires-cable for the
control of the P&T head
CBZ220/CBZ24
DTRX3
DTRX3
DCMX
MATERIAL USED
Control keyboard:
1 DCS2 control keyboard
Video handling:
1 SW164OSM video switcher
2 monitors
4 telecameras
Telemetry handling:
1 DCMX serial data multiplexer
4 DTRX3 receivers
4 PTH310 / PTH311 pan & tilt motors
SW164OSM
Pag. 6
MATERIAL USED
Control keyboard:
1 CBZ220/CBZ24 control keyboard
Video handling:
1 monitor
Telemetry handling:
1 PTH310 / PTH311 pan & tilt motor
1 motorized zoom lens
PTH310 / PTH311 3201