DRRD-12 ... 63
7
Operation
Warning
Danger of injury from moving masses.
Make sure that in the swivel angle of the DRRD
– Nobody can reach in
– No foreign objects can enter
(e.g. by means of an individual protective guard).
For several uninterrupted swivel cycles:
Note
Operational reliability can be impaired by an excessive temperature rise.
Make sure that the following maximum swivel frequency is not exceeded.
Size
Maximum swivel fre
1) 2)
quency
1) Longer reset times are to be expected at temperatures below 0 °C for all Y9/Y10/Y14 versions; it is therefore possible that the
maximum swivel frequency can no longer be reached under certain circumstances
2) The housing temperature of the shock absorber housing should not exceed 60 °C
Tab. 6
26
12
P
[Hz]
2.4
Y9
[Hz]
1.3
Y10
[Hz]
–
Y14
[Hz]
–
16
20
25
32
2.9
2.0
2.0
2.1
1.25 1.4
0.9
0.5
0.6
–
2.9
2.1
1.7
1.0
Festo – DRRD-12 ... 63 – 1607c English
35
40
50
63
1.4
1.5
–
0.45 0.5
0.5
0.6
0.3
0.3
0.3
0.28
0.9
1.1
–