bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.
5. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the machine may
be performed, if needed, only as further precaution, in
addition to the Disassembled Parts Sanitization described
before, but never in lieu of it.
1 Prepare two gallons of a warm (45-60°C, 120-140 °F)
sanitizing solution (100 PPM available chlorine concentration or
1 spoon of sodium hypoclorite diluted with 2 liters of water)
according to your local Health Codes and manufacturer's
specifications.
2 Pour the solution into the bowl(s).
3 Using a brush suitable for the purpose, wipe the solution on
all surfaces protruding above the solution-level and on the
underside of the top cover(s).
4 Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution out
of the bowl(s).
5 Use fresh product to chase any remaining sanitizer from the
bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.
6 ROUTINE MAINTENANCE
1 Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication, worn
or damaged parts. Replace parts as needed.
2 Monthly on MT 1P, MT 2 and MT 3 models: remove the
dust from the condenser filter. A blocked filter will reduce
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source by unplugging it or switching off the 2-pole wall
breaker.
performance and could cause compressor failure.
Remove the only left panel (from faucet side) unscrewing the
two plastic coated screws (see figure 16).
figure 16
ATTENTION
Condenser fins are very sharp. Use extreme caution
when cleaning.
3 Replacement of lighted top cover bulb: remove the fixing
screw placed in the upper part of the top cover, remove the
lower part and replace the bulb (using a 24-28V 21W max
bulb). Reassemble the top cover and replace the fixing
screw.(see figure 17)
6. 1 MAINTENANCE (TO BE CARRIED OUT BY
QUALIFIED SERVICE PERSONNEL ONLY)
1 Monthly on MT 1 model: remove the dust from the
condenser. To do this unplug the unit or switch off the 2-pole
wall breaker and then remove the panels.
2 Annually: remove the panels and clean the inside of the
machine including the base, side panels, condenser, etc.
3 Never remove the insulating jacket from around the suction
tubing of the evaporator (the copper tubing located on the right
side of gear motor). In case the insulating jacket is missing
replace the entire parts with original spare parts from the
supplier.
4 In order to prevent any damages to the dispenser, all
plastics parts must be lubricated only with grease supplied by
the manufacturer or with another lubricating product suitable for
polycarbonate.
IMPORTANT
The electric diagram of the dispenser is located in the
inner part of the dispensing side panel.