disassembled parts in the cleaning solution.
ATTENTION
When cleaning the machine, do not allow excessive
amounts of water around the electrically operated com-
ponents of the unit. Electrical shock or damage to the
machine may result.
3 Do not immerse the lighted top covers in liquid. Wash them
apart with the cleaning solution. Carefully clean their
undersides.
4 In the same manner clean the evaporator cylinder(s) using
a soft bristle brush.
5 Rinse all cleaned parts with cool clean water.
5. 3. 3 SANITIZING
Sanitizing should be performed immediately prior to
starting the machine. Do not allow the unit to sit for
extended periods of time after sanitization.
1 Wash hands with a suitable antibacterial soap.
2 Prepare at least two gallons of a warm (45-60 °C 120-
140 °F) sanitizing solution (100 PPM available chlorine
concentration or 1 spoon of sodium hypoclorite diluted with 2
litres of water) according to your local Health Codes and
manufacturer's specifications.
3 Place the parts in the sanitizing solution for five minutes.
4 Do not immerse the lighted top covers in liquid. Carefully
wash their undersides with the sanitizing solution.
5 Place the sanitized parts on a clean dry surface to air dry.
6 Wipe clean all exterior surfaces of the unit. Do not use
abrasive cleaner.
5. 3. 4 ASSEMBLY
1 Slide the drip tray into place.
2 Lubricate faucet piston, inside auger and outer spiral (see
points A, B and C of figure 11) only with the grease supplied by
the manufacturer or other food grade approved lubricant.
figure 11
3 Assemble the faucet by reversing the disassembly steps
(see figure 10)
4 Fit bowl gasket around its seat.
Note: the largest brim of gasket must face against the rear wall
(see figure 12).
5 Insert the auger into the evaporator taking care to
accompany it to the end so as to prevent it from hitting against
the rear wall (see figure 13).
6 Install the outer spiral. Slide it over the evaporator until its
front notch engages with the exposed end of the auger shaft
(see figure 14).
7 Push the bowl towards the rear wall of the unit until it fits
snugly around the gasket and its front fastening hooks are
properly engaged (see figure 15).
8 On MT 1P model install the lateral tray by reversing the
disassembly steps (see figure 5).
9 Use fresh product to chase any remaining sanitizer from the
15
figure 12
figure 13
figure 14
figure 15