Quick Clean; Keypad Lockout - STA-RITE SUPERMAX VS Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Quick Clean

The SuperMax
®
VS Variable Speed Pump is equipped
with a Quick Clean feature, which can be engaged
to temporarily run at higher or lower speeds ranging
between 300 to 3450 RPM. Once the Quick Clean
duration has elapsed, the pump will automatically return
to the programmed schedule.
Programming Quick Clean:
1. Stop the pump if it is running by pressing the Start/
Stop button.
2. Press the Quick Clean button. The LED above the
Quick Clean button and the "Speed" parameter
LED will flash while editing. See Figure 11.
3450
Figure 11: Setting Speed for Quick Clean
3. Use the "+" and "-" arrows to adjust the speed in
RPM for Quick Clean.
4. Press the Quick Clean button again and the
display will change to Quick Clean duration. The
"Duration" parameter LED will flash while editing.
See Figure 12.
Note: The Quick Clean feature does not have a
start time.
2 : 00
Figure 12: Setting Duration for Quick Clean
5. Use the "+" and "-" arrows to adjust the
duration in hours and minutes for Quick Clean.
6. Press the Start/Stop button and ensure the
LED is illuminated. The pump is now on and
will run the speed and duration set for Quick
Clean.
Note: When the Quick Clean duration ends, the pump
resumes the 24 hour schedule at the point where it
normally would be running at that time. The Quick Clean
duration will not affect the start or stop times of the 24
hour schedule. For example, if Quick Clean runs during
a period overlapping with a later part of SPEED 1 and an
early part of SPEED 2, the start time of SPEED 3 is not
affected.
Note: Pressing/Holding Quick Clean key for more than
three (3) seconds will cancel Quick Clean mode.
Note: During the Quick Clean mode, the pump will not
start with the priming sequence.
Note: It is recommended that you do not set the Quick
Clean duration to 0 HRS. Setting the Quick Clean
duration to 0 HRS will not allow you to change the
duration setting while the motor is running. The motor
will have to be stopped in order to change the Quick
Clean settings if the duration is set to 0 HRS.

Keypad Lockout

Key lockout will not prevent the motor from being
stopped by pressing the Start/Stop button. It will
then be unable to be restarted until the keypad has been unlocked. If the
motor is operating in Keypad Lockout mode, and being controlled through
external controls, it can only run when the Start/Stop LED is illuminated.
The SuperMax VS Variable Speed Pump user interface
has a Keypad Lockout feature to prevent unwanted
changes to the settings. When locked, the keypad will
only accept input from pressing the Display button to
cycle the displayed information on the screen and input
to stop the motor from a press of Start/Stop button.
The keypad can be locked by pressing and holding the
"1" button and the Quick Clean button at the same time
for at least three seconds. "Loc On" will be displayed if
successful.
To unlock the keypad press and hold the "1" button
and the Quick Clean button at the same time for at
least three seconds. "Loc OFF" will be displayed if
successful.
Note: While operating in Keypad Lockout mode the motor
can still be stopped by pressing the Start/Stop button.
However, the motor can not be started again until the
user unlocks the keypad.
SUPERMAX
VS Variable Speed Pump Installation and User' s Guide
®
11

Publicité

Table des Matières
loading

Table des Matières