Behaviour after BASIC OFF ( and similar commands ).
If a transition ( even with zero change ) with a non-default duration is
to be processed, the transition cannot be interrupted by any motion
event in any case.
Lamp is switched off and remains so until any new
0
motion event ( local or remote ) is received.
Lamp is switched off and remains so until after a speci-
fied timeout once a new motion event ( local or remote )
is received.
Timeout:
1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in
1 - 209
1-second resolution
101..200 – 1 minute ( 101 ) to 100 minutes ( 200 )
1-minute resolution
201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour
resolution
210 -
Reserved
254
Lamp is switched off for TIME ( cfg 1 ). It does not wait
255
for a motion event and works normally via current motion
evaluation.
On behaviour ( timeout ):
Parameter Number
Size
Range
Default
11
2
0 – 209, 255
( ON_BEHAVIOUR )
Behaviour after BASIC ON ( and similar commands ).
If a transition ( even with zero change ) with a non-default duration is
to be processed, the transition cannot be interrupted by any motion
event in any case.
Lamp is switched on and remains so until any new
motion event ( local or remote ) is received. It then works
normally via current motion evaluation.
0
Notice – during the day, this mode cannot be ended
remotely due to motion events not being transmitted –
only via local motion sensor if enabled.
Lamp is switched on and remains so until after a speci-
fied timeout once a new motion event ( local or remote )
is received. It then works normally via current motion
evaluation.
Timeout:
1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in
1-second resolution
1 -209
101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) in
1-minute resolution
201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour
resolution
Notice – during the day, this mode cannot be ended
remotely due to motion events not being transmitted –
only via local motion sensor if enabled.
210 -
Reserve
254
Lamp is switched on for TIME ( cfg 1 ). It does not wait
255
for a motion event and works normally via current motion
evaluation.
On behavior time over ( timeout ):
Parameter Number
Size
Range
Default
12 ( ON_TIME_OVER )
2
0 – 209, 255
Time limit to stop waiting for motion after timeout of ON_BEHAVIOUR
or OFF_ON_BEHAVIOUR ( 0-209 ) to prevent staying ON forever when
is no motion.
0
Stop waiting just after timeout.
1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in
1-second resolution
101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) in
1 -209
1-minute resolution
201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in
1-hour resolution
210 - 254 Reserve
255
Never stop waiting before motion.
Sequence On-Off behaviour (timeout):
Parameter Number
Size
Range
13 (ON_OFF_
2
0 – 209, 255
BEHAVIOUR)
Behaviour after a rapid sequence of BASIC ON and BASIC OFF
commands.
The intention is to use a much longer timeout value than the time
after a single ON command which should then be followed by a short
timeout value.
The behaviour is the same as for parameter 10 (OFF_LOCAL_
DISABLE) except:
255 – device ignores ON - OFF sequence and uses OFF behaviour
Sequence Off-On behavior ( timeout ):
Parameter Number
Size
Range
255
14 ( OFF_ON_
2
0 – 209, 255
BEHAVIOUR )
Behaviour after after a rapid sequence of BASIC OFF and BASIC ON
commands.
The intention is to use a much longer timeout value than the time after
a single OFF command which should then be followed by a short
timeout value.
The behaviour is the same as for parameter 11
( ON_LOCAL_DISABLE ) butexcept: 255 – device ignores OFF - ON
sequence and uses ON behaviour.
Sequency timing:
Parameter Number
Size
Range
15 ( SEQUENCY_
1
10 – 50
TIME )
Time in [ 100 miliseconds ] of maximum delay between BASIC ON
and BASIC OFF ( and vice versa ) to consider this as a sequence. It
is typically 1 second, but can be exceptionally longer due to retrans-
missions and overload – in this case, a longer interval can be allowed
( up to 5 seconds ).
Motion Off behaviour ( timeout ):
Parameter Number
Size
Range
16 ( MOTION_
2
0 – 209, 255
DISABLE )
Motion disable timeout after BASIC SET to motion endpoint when the
internal motion sensor is not used for evaluating the behaviour of the
lamp and groups 2 and 3. Events are, however, still transmitted to the
Lifeline, and the lamp can be controlled via remote motion sensors.
BASIC SET to Motion endpoint ignored,
0
Motion sensor still enabled
Internal motion sensor is disabled for specified timeout
after BASIC SET 0x00 to Motion endpoint.
204
Timeout:
1..100 – 1 second ( 1 ) to 100 seconds ( 100 ) in
1 -209
1-second resolution
101..200 – 1 minute ( 101 ) to 100 minutes ( 200 ) in
1-minute resolution
201..209 – 1 hour ( 201 ) to 9 hours ( 209 ) in 1-hour
resolution
210 - 254
Reserve
BASIC SET to Motion endpoint ignored,
255
Motion sensor still disabled
– 40 –
Default
204
Default
204
Default
10
Default
0