Advanced Configuration

For more detailed information, please download the profes-
sional instructions from z-wave.steinel.de.
A. Description of device endpoints:
The functionality of the device is divided to endpoints by
their using.
0 = ROOT
To root summarizes whole device function, to root endpoint is
mapped all functionality from the endpoint 1 and most of the
endpoints 2 and 3.
Device type = On/Off Power Switch
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_BASIC ( v1 )
COMMAND_CLASS_VERSION ( v2 )
COMMAND_CLASS_FIRMWARE_UPDATE_MD ( v3 )
COMMAND_CLASS_MANUFACTURER_SPECIFIC ( v2 )
COMMAND_CLASS_MULTI_CHANNEL ( v4 )
COMMAND_CLASS_DEVICE_RESET_LOCALLY ( v1 )
COMMAND_CLASS_CONFIGURATION ( v1 )
COMMAND_CLASS_POWERLEVEL ( v1 )
COMMAND_CLASS_NODE_NAMING ( v1 )
COMMAND_CLASS_NOTIFICATION ( v4 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
COMMAND_CLASS_SWITCH_BINARY ( v1 )
COMMAND_CLASS_SCENE_ACTIVATION ( v1 )
COMMAND_CLASS_SCENE_ACTUATOR_CONF ( v1 )
COMMAND_CLASS_SWITCH_ALL ( v1 )
COMMAND_CLASS_APPLICATION_STATUS ( v1 )
COMMAND_CLASS_SENSOR_MULTILEVEL ( v4 )
Controlled Command Classes:
COMMAND_CLASS_BASIC ( v1 )
1 = LAMP
To endpoint 1 is mapped basic lamp functionality.
Device type = On/Off Power Switch
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_BASIC ( v1 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
COMMAND_CLASS_SWITCH_BINARY ( v1 )
COMMAND_CLASS_SCENE_ACTIVATION ( v1 )
COMMAND_CLASS_SCENE_ACTUATOR_CONF ( v1 )
COMMAND_CLASS_SWITCH_ALL ( v1 )
COMMAND_CLASS_APPLICATION_STATUS ( v1 )
Controlled Command Classes:
No
2 = MOTION SENSOR
To endpoint 2 is mapped motion sensor (PIR) functionality.
Device type = Sensor - Notification
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_BASIC ( v1 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_NOTIFICATION ( v4 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
Controlled Command Classes:
COMMAND_CLASS_BASIC ( v1 )
Special meaning of BASIC CC:
BASIC CC can activate/temporary deactivate internal motion
sensor using for evaluating the behaviour of the lamp and
groups 2 and 3. Events are, however, still transmitted to the
Lifeline, and the device can be controlled via remote motion
sensors (please also follow the configuration parameter 16).
Basic Set: active ( 0xFF ) / inactive ( 0x00 ) sensor function
Basic Get: get sensor activity
Basic Report: sensor activity status
3 = AMBIENT LIGHT SENSOR
To endpoint 3 is mapped ambient light sensor ( lumines-
cence sensor synchronized with lamp ) functionality.
Device type = Sensor - Multilevel
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_SENSOR_MULTILEVEL ( v4 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
Controlled Command Classes:
No
B. Description of association groups:
0 = ROOT DEVICE
Group 1 – "Lifeline" – only 1 node
Lifeline messages
- Device Reset Locally
- Notifications:
0x09 ( System ) – Hardware failure with manufacturer
proprietary code ( 0x03 )
0x09 ( System ) – Software failure with manufacturer
proprietary code ( 0x04 )
0x07 ( Home security ) – Motion Begin event ( 0x08 )
0x07 ( Home security ) – Motion End event ( 0x00, 0x08 )
- Binary Switch Report – lamp state
- Multilevel Sensor Report – value of internal ambient light
sensor
Motion Begin and Motion End events are sent along with
frames to group 3. If multichannel association is created the
events are sent from motion sensor endpoint.
Switch Report is sent immediately upon a change of status
along with frames to group 2. If multichannel association is
created the events are sent from lamp endpoint.
Multilevel Sensor Report is sent a maximum of once per
1 minute (if the value has changed by least by 3%) and
a minimum of once per 15 minutes (if the value has not
changed). If the ambient light value is old (cannot measure
because of permanent light), the value is not transmitted via
lifeline. Multilevel Sensor Report can be also added to some
other events to send in bulk. If multichannel association is
created the events are sent from light sensor endpoint.
All notifications to lifeline are sent as sensor states regard-
less of sensor settings and states as SLAVE_MODE,
LOCAL_DISABLED and MOTION_ENABLE.
Group 2 – "On/Off control" – max 16 nodes
Group 2 is used for directly controlling Z-Wave devices via
BASIC SET commands through the evaluation of movement
and light as with internal use ( so that all of these devices work
together ). This is intended for use especially with third-party
devices that do not implement reactions for motion events.
BASIC_SET and similar Z-Wave commands are not retrans-
mitted intentionally to slaves and must be sent to slave devic-
es via the controlling device simultaneously. Only for use in
master-slave system, multidevice control is not possible.
– 38 –
Group 2 is evaluated and frames are transmitted there also
in SLAVE_MODE, regardless of LOCAL_DISABLED state
and when MOTION_ENABLE is off ( not using internal motion
sensor just reacts for remote motion events then ).
If multichannel association is created the events are send
from motion sensor endpoint.
Group 3 – "Notification Report" – max 16 nodes
Group 3 sends MOTION_BEGIN and MOTION_END frames.
MOTION_BEGIN frame = Notification 0x07 ( Home
security ) – Motion detection without location ( 0x08 )
MOTION_END frame = Notification 0x07 ( Home security ) –
After first motion detection MOTION_BEGIN is sent. If con-
tinual movement is detected MOTION_BEGIN is sent every
1 minute repeatedly. When motion ends, MOTION_END is
sent 5 seconds after the last motion detection.
Notification to group 3 is sent only when NIGHT_MODE =
ON and MOTION_ENABLE = ON, regardless of
LOCAL_DISABLE state.
All devices in a group should have the same TIME settings in
order that they switch off at the same time.
If multichannel association is created the events are send
from motion sensor endpoint.
Group 4 – "Ambient light" – max 16 nodes
Ambient Light via group 4 is intended to substitute locally
measured LUX values in target devices – so that the network
can have one source of ambient light value. The frame rate
is a value being sent a maximum of once per 2.5 minutes,
and a minimum of once per 15 minutes.
When device already uses remote Ambient light value, then
this value is also retransmitted to group 4.
All devices in such a group should have the same LIGHT
( threshold ) settings in order that night mode is detected at
the same time.
If multichannel association is created the events are send
from light sensor endpoint.
1 = LAMP
The lifeline messages are sent via Root lifeline if not used
multichannel association.
2 = MOTION SENSOR
The lifeline messages are sent via Root lifeline if not used
multichannel association.
Group 2 – its mirror of group 2 of root
Group 3 – its mirror of group 3 of root
3 = AMBIENT LIGHT SENSOR
The lifeline messages are sent via Root lifeline if not used
multichannel association.
Group 2 – its mirror of group 4 of root
C. Configuration description:
Time [ s ]:
Parameter Number
Size
Range
Default
1 ( TIME )
2
5-900
Duration of light after motion detection.
Light threshold [ lx ]:
Parameter Number
Size
Range
Default
2 ( LIGHT )
2
2-2000, 0
2000/poti state
0 – run Learn ambient light sequence.
2000 - is used as daylight ( always night mode ).
Value can be controlled via potentiometer – potentiometer value is
used as the default value and any potentiometer movement rewrites
the current setting.
Motion Sensor (PIR) Sensitivity [%]:
Parameter Number
Size
Range
5 ( SENSITIVITY )
1
2-100
Value can be controlled via potentiometer – potentiometer value is
used as the default value and any potentiometer movement rewrites
the current setting.
Brightness measuring interval [ minutes ]:
Parameter Number
Size
Range
6 ( BRIGHTNES
1
5-120, 0
MEAS INTERVAL )
Interval for ambient light measuring when lamp is on ( lamp switches
off shortly and measures ). 0=function is off.
Use External Ambient Light Value:
Parameter Number
Size
Range
8 ( GLOBAL_LIGHT )
1
0/1
When GLOBAL_LIGHT mode is ON – device overrides its own light
sensor values and uses Light report values from any Z-Wave light
sensor instead – this has to be configured appropriately to send light
automatically.
If the last remote light level value is older than 30 minutes, the internal
light value is used again until the next external value is received.
Disable local control:
Parameter Number
Size
Range
9 ( SLAVE_MODE )
1
0-4
Bit Field:
bit
7
6
5
4
3
2
"Stupid"
-
-
-
-
-
mode
"Stupid" mode ( bit 2 = 1 ):
- has higher priority then slave mode.
- lamp is permanently on ( usefull for simple power wall
switch controlling ).
Slave mode ( bit 0 = 1 ):
- only if included in Z-Wave network
- usefull for controlling via third-party sensor
- lamp is directly controlled via Z-Wave, internal sensors
are not used for controlling it.
Central unit checking ( bit 1 = 1 ):
( usefull especialy for controlling via gateway )
When Slave bit is 0:
- lamp signalises fail of lifeline connection ( if this bit is zero
fail of lifeline connection is not signalised )
When slave bit is 1:
- lamp checks presence of Z-Wave device in lifeline group
( gateway ). If it is not present for 2 minutes ( testing re-
peatedly every 30 seconds ) device switches to normal
mode in the same way as after the end of local disabled
mode ( ON_BEHAVIOUR )
180
- The device checks every 1 minute for recovery of
Lifeline connection.
- if no lifeline specified - it works in normal mode
Be careful with this option, lamp stops using it's own
motion sensor in Slave and Stupid mode.
Off behavior ( timeout ):
Parameter Number
Size
Range
10 ( OFF_
2
0 – 209,255
BEHAVIOUR )
– 39 –
Default
100
Default
0
Default
1
Default
2
1
0
Central unit
checking
Slave
in slave
mode
mode
Default
10