Télécharger Imprimer la page

Fuse Check/Replacement; Detergent Tank Cleaning - Nilfisk ALTO SCRUBTEC 545B Manuel D'utilisation

Masquer les pouces Voir aussi pour ALTO SCRUBTEC 545B:

Publicité

Les langues disponibles

Les langues disponibles

FUSE CHECK/REPLACEMENT

1.
Disconnect the battery connector (12).
2.
Move aside the recovery water drain hose (16).
3.
Remove the battery charger cable (I, Fig. 8), if equipped, from the cable holder (J).
4.
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the panel (B).
5.
Check/replace the following fuses:
C)
Brush deck fuse F1: (40 A)
D)
Vacuum system fuse F2: (30 A)
E)
Drive system fuse F3: (30 A) (*)
F)
Signal circuits fuse F4: (3 A)
G)
Brush/pad-holder release fuse F5: (20 A)
H)
Pump fuse F6: (3 A)
(*)
Only for SCRUBTEC 545BL, 553BL e BOOST 5
6.
Perform steps 1 to 4 in the reverse order.
F

DETERGENT TANK CLEANING

(For machines with Chemical Mixing System)
Clean the detergent tank (45) according to the following procedure:
1.
Drive the machine to the appointed disposal area.
2.
Open the cover (22) and check that the recovery tank (21) is empty, otherwise empty it with the drain hose (16). Close the
cover (22).
3.
Carefully lift the tank (40).
4.
Unscrew the plug (46) and disconnect the hose (50) from the tank (45).
5.
Remove the tank.
6.
Wash the tank in the appointed disposal area.
7.
Install the tank (45) and connect it to the hose (50).
8.
After draining the detergent tank, drain the Chemical Mixing System too by running the system with clean water only.
NOTE
Drain the Chemical Mixing System when it is dirty/clogged and after long inactivity/uncleaning of the machine.
9097054000(2)2009-06 A
Bedienungsanleitung auf www.gluesing.net
A
G
H
A
SCRUBTEC 545B – 545BL – 553B – 553BL – BOOST 5
USER MANUAL
B
A
J
I
Figure 8
ENGLISH
A
D
E
K
C
P100110
27

Publicité

loading