Fracarro D-Matrix 4S Instructions D'emploi page 51

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The column of lists in fi gure 10 show:
the program name, the input it comes from, the program position (the lower the number the
higher the priority), the assigned LCN value (0 if not specifi ed), the assigned LCN HD (0 if not
specifi ed) the band used.
The position (or priority) determines the importance of the programs and, therefore, which will be
cut fi rst if there is a bitrate overfl ow, for example: 1 = top priority, therefore the most important
one and the one to save (see Programming Indications).
The LCN and LCN HD parameters must be set so that each generated output program, including
among a number of devices, has a distinct value. If this is not to be specifi ed, input 0.
among a number of devices, has a distinct value. If this is not to be specifi ed, input 0.
To remove a program from the output list click on
The bottom section of the table gives data about the band occupied by just the output programs
(sum of the programs, not considering the tables for the common TS and PID) and the indication
of the interval of programs viewed out of the total.
of the interval of programs viewed out of the total.
By clicking on the icon
management.
By clicking on the program
In the fi rst table certain program parameters can be changed, by writing directly in the space,
such as: name, provider, SID, the PMT PDI. When a parameter has been changed it can be reset
such as: name, provider, SID, the PMT PDI. When a parameter has been changed it can be reset
(returned to the original shown in the second column) by clicking on the arrow
the change space. The last parameter in the list opens a dropdown menu to select how to set
the program so that it is declared as free to air or encrypted by the decoder.
always automatic: the program is declared as free to air automatically if it is decrypted by
the cam.
always yes: the program is always declared as free to air even if it is not decrypted by the
cam.
always no: the program is always declared as encrypted, even if it is decrypted by the cam.
unchanged: the program is declared free to air if it is not changed or if it is not sent to the
cam for decryption.
The second table is to manage the PID list. It can be changed by writing in the following PID in
the space: PCR video stream, audio stream, teletext, MHP, application information table.
In the last column in this table, by clicking on the symbol certain actions can be taken with each
program PID:
program PID:
to delete the PID (the entire line for the deleted PID is highlighted in grey),
in the right hand column, access is given to more advanced program
, the following screen opens:
Fig. 11
in the right hand column.
51
on the right of

Publicité

Table des Matières
loading

Table des Matières