CoolAir SP950
7.5
Extracting condensation (SP950 with SP950T roof
evaporator unit only)
The condensated water which accumulates due to the way the system works is auto-
matically extracted at intervals during operation.
You can pump out the condensated water manually when necessary:
I
NOTE
Before winter, extract the condensed water from the system to avoid
damage caused by freezing water.
➤ Switch off the system.
➤ Press and hold the
➤ In addition, press the
✓ The firmware version appears in the digital display for 5 seconds.
000
then appears in the digital display and the system starts the extraction
process for 15 seconds.
You can now let go of the
✓ The compressor and the fan do not switch on.
✓ The system switches off automatically.
I
NOTE
To stop the extraction early press the
off.
If you want to tilt the driver's cab, you first need to drain the condensation manually.
➤ Keep repeating this procedure until the pump starts making a clearly audible,
loud noise while draining.
✓ There is then no more condensation left in the system.
➤ Press the
button until the pump switches off.
A
NOTICE!
Avoid prolonged dry periods as this can damage the pump (indicated
by loud noise while draining).
EN
and – buttons simultaneously.
button briefly.
and – buttons.
Using the parking cooler
button until the pump switches
17