Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
Symptom
Unit not hot enough.
Unit too hot.
No heat.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please
contact the nearest authorized Hatco Service agency or Hatco
for assistance. To locate the nearest Service agency, log onto
the Hatco website at www.hatcocorp.com and click on
Find Service agent, or contact the Hatco Parts and Service
Team at:
Telephone: 800-558-0607 or 414-671-6350
e-mail:
partsandservice@hatcocorp.com
Fax:
800-690-2966 or 414-671-3976
Form No. SWm-0914
Probable Cause
Infinite switch set too low.
Heating element not working.
Infinite switch not working properly.
Low water level in well.
Voltage supplied is incorrect.
Infinite switch set too high.
Infinite switch not working properly.
No water in well.
Voltage supplied is incorrect.
Unit not turned on.
Circuit breaker tripped.
Infinite switch not working properly.
Heating element not working.

TROUBLESHOOTING GUIDE

ELECTRIC SHOCK HAzARD: Turn OFF infinite switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
adjust infinite switch to a higher setting.
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
Fill each well with hot tap water until the water is
between 1/2" (13 mm) and 1" (25 mm) deep.
Verify correct voltage is supplied to unit. Low supply
voltage will cause improper heating.
adjust infinite switch to a lower setting.
Contact authorized Service agent or Hatco for
assistance.
Fill each well with hot tap water until the water is
between 1/2" (13 mm) and 1" (25 mm) deep.
Verify correct voltage is supplied to unit. High supply
voltage will cause unit to overheat and my damage
the unit.
Turn on unit.
Reset circuit breaker. If circuit breaker continues to
trip, contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
9
WARNING
Corrective Action

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Sw2-7qtSw2-11qt

Table des Matières