PROBLEM
The vacuum bag is
not properly and/or
correctly sealed.
In the case of other problems or questions contact the supplier or SARO .
Version 12.10 Art. 0894552
CAUSE
The vacuum bag is being placed
incorrect on the sealing bar.
The sealing time is too long or too short.
The silicone rubber in the silicone holder
is damaged or worn.
The Teflon tape is damaged.
The inside of the vacuum bag opening is
contaminated or greased.
SOLUTION
Place the vacuum bag neatly and
smoothly on the sealing bar. Ensure that
the opening of the bag is always within
the vacuum chamber.
Adjust the sealing time longer or shorter.
Replace the silicone rubber.
Replace the Teflon tape
Clean the vacuum bag's opening.