saro SVM Manuel D'utilisation page 43

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BEDIENUNGSANLEITUNG/ USER MANUAL/ MANUEL D'UTILISATION
Saro
Set/change function values
The following steps must be followed to change the function values for vacuum and/or seal :
Press the FUNCTION SELECT Key to select the required function. The function light will light up when the function is
selected.
Press the [+ / STOP VACUUM] or [- / STOP] keys for incrementing or decrementing the function values respectively. It
takes 0.5 seconds before the value begins to change.
After changing the value(s) the machine must run through the cycle once (see previous page) to record the values.
Vacuum function
The vacuum function value can be incremented or decremented per second with a maximum of 99 seconds and a
minimum of 2 seconds.
If while changing the vacuum function setting the [+ / STOP VACUUM] or [- / STOP] key is held down then the first 5
seconds will be incremented or decremented per second. Then intervals of 10 seconds will appear. If the key is released
then the settings can be changed again per second.
Sealing function
The seal function setting can be increased or decreased with a maximum of 6.0 sec. and a minimum of 0.5 sec.
If while changing the seal function setting the [+ / STOP VACUUM] or [- / STOP] key is held down then the first 0.5
seconds will be incremented or decremented per 0.1 second. Then intervals of 1.0 second will appear. If the key is
released then the settings can be changed again per 0.1 second.
Service programs control panel
The control panel is also equipped with a number of service programs that can be useful during regular maintenance or
repairs. The conditioning program for the pump is the most used service program (see explanation on page 45).
Contact the supplier or SARO for more information about the use of other service programs.
Version 12.10 Art. 0894552