OUTPUT SUPPLIED

The charts alongside will allow you to determine
the output supplied either by reading the
number of rotations or by reading the down-
stream pressure of the gas valve (point 1).
Example:
• Operation with PREMIX RX 250 S/PV
• Natural gas G31 PCI 9.45 kWh/Sm
• Pressure on point 1 = -21 mbar.
The burnt power corresponds to 200 kW.
The burnt power corresponds to 200 kW.
Going back in vertical in the diagram, until inter-
crossing the outlined straight line, you can esti-
mate the value of the number of rotation on the
scale of the left-hand ordinates: in this case
4750 turns/min.
For an exact reading of the number of rotations,
it is available a control box interface kit.