Télécharger Imprimer la page

Xylem GOULDS RED JACKET Série Mode D'emploi page 2

Publicité

Les langues disponibles

Les langues disponibles

Definitions
Indicates the presences of a hazard
WARNING
which can cause severe personal
injury, death or substantial property
damage if the warning is ignored.
Indicates the presences of a haz-
CAUTION
ard which will or can cause severe
personal injury, death or substantial
property damage if the warning is
ignored.
Indicates special instructions on
NOTICE
installation, operation or mainte-
nance which is important but not
related to personal injury hazards.
Very Important Safety Information
Always follow these rules to avoid bodily injury or
property damage.
To reduce risk of electric shock, con-
WARNING
nect only to a properly-grounded
electrical circuit.
TABLE A: RECOMMENDED WIRE AND FUSE SIZES
Nameplate
Rated VAC
HP
115
½
230
115
¾
230
115
1q
230
115
230
NOTE: Conversion instructions for dual voltage (115/230 volts) can be found on the wiring diagram instructions on the motor
nameplate
2
Branch
Fuse Amps
0-50 ft.
15
14
15
14
15
14
15
14
20
12
15
14
20
10
15
14
WARNING
WARNING
NOTICE
CAUTION
Wire Size Chart Distance in Feet – Meter to Motor
51-100 ft.
101-200 ft.
14
10
14
14
14
10
14
14
12
8
14
14
10
8
14
14
Risk of electric shock — this pump
has not been investigated for use in
swimming pool areas.
Before installing or servicing a
pump, check to see that the power
source is disconnected to avoid any
possible electrical shock hazard.
Also, make sure the electrical sup-
ply agrees with the motor wiring
and that the circuit is properly
grounded before operation.
Conformance with local and state
electrical codes is mandatory. If you
are ever in doubt, call a licensed
electrician or your local power com-
pany.
Dual-voltage models are factory
pre-wired for 115 volt operation
on 1/2 and 3/4 hp models and 230
volt on 1 and 1‑1/2 hp models. For
all electrical connections, a separate
line with fused switch should be run
from the meter or breaker box and
properly grounded.
201-300 ft.
301-400 ft.
8
8
14
14
8
8
14
14
6
6
12
12
6
4
12
12
401-500 ft.
8
12
8
12
6
10
4
10

Publicité