Panasonic EYFPA1J Instructions D'utilisation page 17

Masquer les pouces Voir aussi pour EYFPA1J:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Initializing all settings
Factory settings
• Torque clutch setting: "F" (torque con-
trol function off)
• Snug point detection level → L1
• Cross thread reduction function → R0
• Rundown error detecting function → 0
• Maintenance interval alarm function
→ 0
• Radio signal range limitation function
→ C0
• Buzzer setting → b0
• LED light setting → d1
• Speed control setting → P0
• This section explains how to revert all tool
settings to their default values at the time of
shipment from the factory.
• The error display will be turned off.
1. Set the tool to the setting configuration
mode.
(See page 13.)
. Press the C button.
The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and
lower bars of the battery flash on and off.
[Fig.27]
3. Press the OK button to accept the select-
ed setting.
The control panel will stop flashing and
light up.
Checking tool settings
• When the tool stops, the current setting
value will be displayed for approximately 
seconds.
• The setting status cannot be checked while
the tool panel is off. Depress the trigger
switch once to turn on the panel.
Checking the status of the
torque clutch and sung point
detection level setting and
Buzzer settings
Press the A button.
The torque clutch and sung point detection
level setting and buzzer setting values will be
displayed (in that order).
Example: If the torque clutch is set to 30 and
sung point detection level setting L1 and the
buzzer is set to sound at the green indicator,
"30" → "L1" → "b1"
Checking the status of the
LED light and rundown error
detecting function and speed
control function settings
Press the B button.
The LED light and tightening time and speed
control setting will be displayed (in that order).
Example: If the LED light mode is set to L1
and the tightening time is set to 0 and speed
control is set to ON,
"d1" → "20" → P0
Checking the tool circuits and
the status of the cross thread
reduction function settings
Press the D button.
The tool circuits and cross thread reduction
function settings will be displayed (in that
order).
Example: "H3" → "R1"
Display
H
H1
NOTE:
When other tools are in the area which
are not set, they may accidentally
receive a signal when setting the tool
by remote control.
Set the tool in another room if possible
or keep a fair distance to avoid this situ-
ation.
- 17 -
EN
EN
Tool circuit
EYFPA1
EYFNA1

Publicité