before pressing the OK button and then
pressing the OK button.
Pressing the A button toggles the dis-
play between the snug point detection
level setting value and the number of
torque stages setting value.
The tool ships with the snug point
detection level set to "L1."
When the number of torque stages has
been set as shown below, the snug
point detection level cannot be switched
from "L1" to "L."
Number of torque stages
Model
EYFPA
EYFNA
Cross thread reduction func­
tion
The tool runs in reverse approximately 360°
before running forward to assist in the align-
ment of the threads to help reduce cross
threads.
1. Set the tool to setting configuration mode.
(See page 13.)
. Press the D button once.
The cross thread reduction function setting
value will be displayed.
3. Press the
and
setting to ON or OFF.
Display
R0
R1
4. Press the OK button to accept the new
setting.
Rundown error detecting func­
tion
The rundown error detecting function causes
a red indicator to flash if work ends more
quickly than a set time, for example due to
retightening of a previously tightened fastener
or binding of the screw's thread.
1. Set the tool to setting configuration mode.
(See page 13.)
. Press the B button twice.
The rundown error detecting function set-
ting value will be displayed.
3. Press the
and
time as desired.
setting
1 to 30
1 to 30
buttons to change the
Function
OFF
ON
buttons to change the
- 1 -
Operation
Display
4. Press the OK button to accept the new
setting.
When the cross thread reduction function
is ON, the set time will be counted after
the tool operates in reverse for approxi-
mately 360°.
Maintenance interval alarm
function
The maintenance interval alarm function locks
the tool so that it can no longer be operated
once a set number of tightening operations
has been performed. This function is conve-
nient when regularly inspecting tool perfor-
mance, for example.
1. Set the tool to setting configuration mode.
(See page 13.)
. Press the C button twice.
The setting value will be displayed.
3. Press the
and
desired value.
Operation
Display

1
0
4. Press the OK button to accept the new
setting.
NOTE:
When the remaining number of tighten-
ing operations is 10,000 or less, the
display will alternate between "Setting"
and "1." When the remaining number
of tightening operations reaches 0, the
value "0" will flash on the display.
To delay the inspection while retaining
the current tightening operation count
value, select a new setting value that is
greater than the current setting value.
To reset the count to 0, initialize the tool
(see page 17).
The maximum tightening operation
count value is 0,000. Operations in
excess of 0,000 will not be counted.
Seconds
30
3 seconds
1
0.1 seconds
0
OFF
buttons to set the
Number of tightening
operations
0,000
10,000
OFF