Velleman DVM860BL Mode D'emploi page 4

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Overload Protection : F 200mA/250V fuse (quick-acting) for the µ A, mA ranges. The 2A and 10A range are unfused.
Max. Input Current : INPUT jack: 200mA, 10A jack: 10A.
Voltage Drop
: 200µ V, 20mA, 2A: 20mV, 2000µ A, 200mA, 10A-range: 200mV.
Frequency Range
: 40 to 400HZ
Response
: average response, calibration in rms of a sine wave.
5.2.5. DC Current (with optional clamp AC97)
meter
DC clamp
meter
DC clamp
Overload Protection : 250V DC or AC rms
Max. Input Voltage : 200mV
5.2.6. AC Current (with optional clamp AC97)
meter
AC clamp
meter
AC clamp
Overload Protection : 250V DC or AC rms
Max. Input Voltage : 200mV
Frequency Range
: 40 to 400HZ
Response
: average response, calibration in rms of a sine wave.
5.2.7. Resistance
Range
200
2k
20k
200k
2M
20M
Open-Circuit Voltage : ±0.25V
Overload Protection : 250V DC or AC rms
5.2.8. Temperature
Range
Resolution
-20°C to 0°C
Accuracy
0°C to 400°C
400°C to 1000°C
Overload Protection : 250V DC or AC rms
DVM860BL
Range
Resolution
0.1mV/0.1A
200A
0.1A/0.1mV
0 to 200A
1mV/1A
2000A
1A/1mV
0 to 2000A
Range
Resolution
0.1mV/0.1A
200A
0.1A/0.1mV
0 to 200A
1mV/1A
2000A
1A/1mV
0 to 2000A
Resolution
0.1
0.001k
0.01k
0.1k
0.001M
0.01M
-20°C to 1000°C
1°C
±5.0% of rdg + 4 digits
±1.0% of rdg ± 3 digits
±2.0% of rdg ± 3 digits
±1.2% of rdg + 3 digits
±1.2% of rdg + 3 digits
±1.5% of rdg + 5 digits
±1.5% of rdg + 5 digits
Accuracy
±1.0% of rdg ± 3 digits
±1.0% of rdg ± 1 digit
±1.0% of rdg ± 5 digits
0°F to 50°F
50°F to 750°F
750°F to 1800°F
- 4 -
Accuracy
typical ±2.0%
typical ±2.0%
Accuracy
typical ±3.0%
typical ±3.0%
0°F to 1800°F
1°F
±5.0% of rdg + 4 digits
±1.0% of rdg ± 3 digits
±2.0% of rdg ± 3 digits
VELLEMAN

Publicité

Table des Matières
loading

Table des Matières