Activate the switch (1.) bringing it to position ON (I), the vacuum pump starts and you then start air suction using the
attachment for containers. To stop suction, you need to activate the switch again (1.) bringing it to position OFF (0).
-
The vacuum gauge (2.) indicates the vacuum level created by the pump inside the container. During machine operation, the
hand will move from the yellow zone (vacuum minimum level) to the red zone (maximum vacuum level).
-
The vacuum gauge hand has initial strong oscillations, due to air extraction; when the quantity of air in the tubes decreases
the hand stabilises.
VACUUM PACKING WITH REBER ACCESSORIES AND CONTAINERS
(For this operation you will need containers with vacuum valve lids; only use containers suitable for vacuum packing, in plastic or
tempered glass).
-
Insert the tube of the attachment for containers in the air intake.
-
Fill the container leaving at least 3 cm. of free space from the upper edge, and position the lid.
-
Slightly unscrew the plug on the lid so the valve is released; (ATTENTION: the plug must NOT be unscrewed completed, a
few turns is enough).
-
Position the attachment for containers on the plug.
-
Start the vacuum pump by pressing the start switch (1.) bringing it to the ON position (I).
-
Once the desired vacuum level is reached, shut-off suction pressing the switch (1.) and bringing it to the OFF (O) position.
-
Remove the attachment for containers from the lid and screw in the plug until the valve is blocked.
-
To open the container slightly unscrew the plug until the valve is released, then move the valve so air enters the container.
VACUUM PACKING WITH REBER UNIVERSAL LIDS
(The REBER universal lids in various measurements to adapt to containers, jars, bowls, saucepans and dishes, for normal household
use, with a diameter of 4 to 22 cm.)
-
Proceed as per vacuum packaging in the container, taking care the edge of the container used sticks perfectly to the universal
lid seal.
-
In case of prolonged use on the same container, the seal of the lid can have a groove left by the edge of the container; to
eliminate any use problem, you must rotate the gasket on the opposite side; then the groove with shortly disappear by itself.
-
The seal of the lids can be removed for washing; once dry they must be correctly positioned.
VACUUM PACKING WITH LARGE ATTACHMENT FOR GLASS JARS
(For this operation, you need to use the specific lids for glass jars code 6706 A and the large attachment for glass jars model JUNIOR
6704 A)
-
Insert the plastic tube of the attachment for glass jars in the suction air intake (4.) on the machine.
-
Fill the jar leaving at least 3 cm. of free space from the upper edge.
-
Position the lid on the glass jar.
-
Position the large attachment on the jar and push to block its seal on the glass jar.
-
Turn the top part of the attachment to the CLOSE position.
-
Start the vacuum pump by activating the switch (1.) bringing it to the ON position.
(I).
-
Once the desired vacuum level is reached, press the switch (1.) to bring it to the OFF (0) position and stop suction.
-
Turn the top part of the attachment to the OPEN position.
-
Remove the attachment for containers from the jar and screw in the ring nut until the lid is blocked.
-
To open the jar, unscrew the ring nut and lift the lid with the specific REBER lid lever code 6713 A to allow air into the jar.
UNDERSTAND AND RESOLVE DOUBTS ON CORRECT USE OF THE APPLIANCES FOR VACUUM PACKING
The appliance is tested at the time of manufacturing with at least 3 vacuum/sealing cycles. If you are having difficulty during use, doubts
or problems, you can proceed with some tests to check the efficiency of the product.
Auto-diagnosis tests
Internal component operation:
9-
With the cover open, press the start button and close the air press with a finger. (image 6)
10-
If the hand on the vacuum gauge reaches red (and/or the red led switches on) and sealing automatically starts, internal
operation is correct.
11-
If the hand on the vacuum gauge reaches red (and/or the red led switches on) but sealing does not automatically start, you
need to set the machine for automatic operation and try again.
12-
If the hand on the vacuum gauge does not reach red (and/or the red light does not switch on) the vacuum pump is damaged
or there is an air leak in the internal tubes circuit - contact a support centre for repair.
Operation of the cover and gaskets on the vacuum chamber:
9-
Close the cover on the machine (without inserting the bag), press the start button and exert light pressure on the cover to start
the automatic cycle. (image 7)
10-
If the hand on the vacuum gauge reaches red (and/or the red led switches on) and sealing automatically starts, machine
operation is correct.
11-
If the hand on the vacuum gauge reaches red (and/or the red led switches on) but sealing does not automatically start, you
need to set the machine for automatic operation and try again.