OPERATION
4. Raise squeegee and wipe it down with a dry cloth.
Store squeegee in the up position to prevent
squeegee damage.
5. Clean machine with an all purpose cleaner and
damp cloth.
ATTENTION: Do not power spray or hose off
machine. Electrical component damage may
result.
6. Recharge batteries, if necessary.

WEEKLY MAINTENANCE

(Every 20 Hours of Use)
1. Check fluid level in battery cells (See BATTERY
CHARGING).
2. Clean battery tops from corrosion (See BATTERY
CHARGING).
3. Check for loose or corroded battery cables.

MONTHLY MAINTENANCE

(Every 80 Hours of Use)
1. Flush out tanks and solution lines. Pour 750ml (24
oz) of an acetic acid solution with 11.3L (3 gal) of
hot water, 60_C (140_F) max., into solution tank.
Over a floor drain, activate solution flow briefly to
fill solution line. Shut off power and let machine set
over night. Rinse with clean water afterwards.
FOR SAFETY: When using machine, follow
mixing and handling instructions on chemical
containers.
2. Lubricate all linkage pivot points with silicone
spray then coat with a water resistant grease to
maintain a smooth operation.
3. Check machine for water leaks and loose nuts and
bolts.

QUARTERLY MAINTENANCE

(Every 250 Hours of Use)
Inspect motors for carbon brush wear. Replace
brushes when worn to a length of 10mm (0.38 in ) or
less. Contact an Authorized Service Center for carbon
brush inspection.
ATTENTION: Contact an Authorized Service
Center for machine repairs. Machine repairs
performed by other than an authorized person will
void the warranty.
14
Home
Find... Go To..

BATTERY MAINTENANCE

WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
FOR SAFETY: When servicing machine, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
1. Check the specific gravity using a hydrometer to
determine the charge level and the condition of the
batteries (Figure 25). If one or more of the battery
cells read lower than the other battery cells (0.050
or more), the cell is damaged, shorted, or is about
to fail. Check the hydrometer readings against the
following chart to determine the remaining battery
charge level.
NOTE: Do not take readings immediately after adding
distilled water. If the water and acid are not thoroughly
mixed, the readings may not be accurate.
FIG. 25
SPECIFIC GRAVITY
at 27° C (80°F)
1.265
1.223
1.185
1.148
1.110
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 27_C (80_F),
the reading must be temperature corrected. Add or
subtract to the specific gravity reading 0.004, 4 points,
for each 6_C (43_F) above or below 27_C (80_F).
Speed Scrub 2001 Battery (03- -06)
BATTERY
CHARGE
100% CHARGED
75% CHARGED
50% CHARGED
25% CHARGED
DISCHARGED